An improved laser photo-detachment diagnostic for negative ion density measurement

Abstract A photo-detachment Langmuir probe is a crucial tool because it gives a point measurement of negative ion density. The detection circuitry of a photo-detachment diagnostic with nanosecond laser pulses is critical for the accuracy of the results. Applying the electromagnetic theory to the design of the photo-detachment system has allowed it to stabilize its frequency response up to ~445 MHz, providing a significantly higher time resolution than in a common photo-detachment circuit setup. A systematic design rule is given in this paper to standardize the proper circuit. The new standard allows comparison between laboratories without concern for electronic parameter differences. The high-time resolution result shows three different peaks in the photo-detached electron current. This paper identified that the first peak is the most correlated to negative-ion density information, and the second and third peaks are related to background electrons interacting with build-up potential.

Authors

Institutions

Publication Details

Journal
Journal of Instrumentation
Published
2024-11-01
DOI
https://doi.org/10.1088/1748-0221/19/11/p11002
Citations
1
Primary Topic
Particle accelerators and beam dynamics
Type
article
Field-Weighted Citation Impact
1.30
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

An improved laser photo-detachment diagnostic for negative ion density measurement

E. Rattanawongnara, K. Nagaoka, M. Osakabe, K. Tsumori et al.
1 citations
Journal of Instrumentation
Particle accelerators and beam dynamics
1.30
article

An improved laser photo-detachment diagnostic for negative ion density measurement

E. Rattanawongnara, K. Nagaoka, M. Osakabe, K. Tsumori, H. Nakano
article en
1 citations

Abstract

Abstract A photo-detachment Langmuir probe is a crucial tool because it gives a point measurement of negative ion density. The detection circuitry of a photo-detachment diagnostic with nanosecond laser pulses is critical for the accuracy of the results. Applying the electromagnetic theory to the design of the photo-detachment system has allowed it to stabilize its frequency response up to ~445 MHz, providing a significantly higher time resolution than in a common photo-detachment circuit setup. A systematic design rule is given in this paper to standardize the proper circuit. The new standard allows comparison between laboratories without concern for electronic parameter differences. The high-time resolution result shows three different peaks in the photo-detached electron current. This paper identified that the first peak is the most correlated to negative-ion density information, and the second and third peaks are related to background electrons interacting with build-up potential.

Journal of InstrumentationVol. 19(11)
The Graduate University for Advanced Studies, SOKENDAI (JP), National Institute for Fusion Science (JP), Nagoya University (JP)
Affordable and clean energy
Openalex Percentile: Top 12%
Particle accelerators and beam dynamics
1.30
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

An improved laser photo-detachment diagnostic for negative ion density measurement — E. Rattanawongnara, K. Nagaoka, et al. · Journal of Instrumentation (2024) | TGRS Research Map | TGRS