Multi-Level Noise Sampling From Single Image for Low-Dose Tomography Reconstruction

Low-dose digital radiography (DR) and computed tomography (CT) become increasingly popular due to reduced radiation dose. However, they often result in degraded images with lower signal-to-noise ratios, creating an urgent need for effective denoising techniques. The recent advancement of the single-image-based denoising approach provides a promising solution without requirement of pairwise training data, which are scarce in medical imaging. These methods typically rely on sampling image pairs from a noisy image for inter-supervised denoising. Although enjoying simplicity, the generated image pairs are at the same noise level and only include partial information about the input images. This study argues that generating image pairs at different noise levels while fully using the information of the input image is preferable since it could provide richer multi-perspective clues to guide the denoising process. To this end, we present a novel Multi-Level Noise Sampling (MNS) method for low-dose tomography denoising. Specifically, MNS method generates multi-level noisy sub-images by partitioning the high-dimensional input space into multiple low-dimensional sub-spaces with a simple yet effective strategy. The superiority of the MNS method in single-image-based denoising over the competing methods has been investigated and verified theoretically. Moreover, to bridge the gap between self-supervised and supervised denoising networks, we introduce an optimization function that leverages prior knowledge of multi-level noisy sub-images to guide the training process. Through extensive quantitative and qualitative experiments conducted on large-scale clinical low-dose CT and DR datasets, we validate the effectiveness and superiority of our MNS approach over other state-of-the-art supervised and self-supervised methods.

Authors

Institutions

Publication Details

Journal
IEEE Journal of Biomedical and Health Informatics
Published
2024-11-11
DOI
https://doi.org/10.1109/jbhi.2024.3486726
Citations
1
Primary Topic
Medical Imaging Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.40

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Multi-Level Noise Sampling From Single Image for Low-Dose Tomography Reconstruction

Yifei Long, Fangxiao Cheng, Zhifan Gao, Weiwen Wu et al.
1 citations
IEEE Journal of Biomedical and Health Informatics
Medical Imaging Techniques and Applications
0.40
article

Multi-Level Noise Sampling From Single Image for Low-Dose Tomography Reconstruction

Yifei Long, Fangxiao Cheng, Zhifan Gao, Weiwen Wu, Jianjia Zhang, Guang Yang
article en
1 citations

Abstract

Low-dose digital radiography (DR) and computed tomography (CT) become increasingly popular due to reduced radiation dose. However, they often result in degraded images with lower signal-to-noise ratios, creating an urgent need for effective denoising techniques. The recent advancement of the single-image-based denoising approach provides a promising solution without requirement of pairwise training data, which are scarce in medical imaging. These methods typically rely on sampling image pairs from a noisy image for inter-supervised denoising. Although enjoying simplicity, the generated image pairs are at the same noise level and only include partial information about the input images. This study argues that generating image pairs at different noise levels while fully using the information of the input image is preferable since it could provide richer multi-perspective clues to guide the denoising process. To this end, we present a novel Multi-Level Noise Sampling (MNS) method for low-dose tomography denoising. Specifically, MNS method generates multi-level noisy sub-images by partitioning the high-dimensional input space into multiple low-dimensional sub-spaces with a simple yet effective strategy. The superiority of the MNS method in single-image-based denoising over the competing methods has been investigated and verified theoretically. Moreover, to bridge the gap between self-supervised and supervised denoising networks, we introduce an optimization function that leverages prior knowledge of multi-level noisy sub-images to guide the training process. Through extensive quantitative and qualitative experiments conducted on large-scale clinical low-dose CT and DR datasets, we validate the effectiveness and superiority of our MNS approach over other state-of-the-art supervised and self-supervised methods.

IEEE Journal of Biomedical and Health InformaticsVol. 29(2)
Sun Yat-sen University (CN), Peking University (CN), Imperial College London (GB)
Medical Research Council
Openalex Percentile: Top 33%
Medical Imaging Techniques and Applications
0.40
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.