Broadband Powerline Communication for Low-Voltage Microgrids

The distributed-element transmission line model is modified to account for proximity effects in multiconductor cables and frequency dependent dielectric behaviour providing an accurate prediction of channel attenuation at broadband power line communication frequencies (1–100 MHz). The modified model is verified with scattering parameter measurements and then used as a building block for complex microgrid network modelling. Powerline communication performance tests are conducted using the HomePlug GreenPHY and HomePlug AV. The AV operates successfully up to 600 m on star feeders and on complex radial feeders in the presence of power converter noise. The GreenPHY operates up to 450 m on star feeders and on radial feeders with long branches. However, it cannot connect reliably on radial feeders with short branches due to frequency selective notching. Functionality requires link attenuation less than −60 dB at 30 MHz and the absence of notches that penetrate below −70 dB within the band (1.8–30 MHz). Due to the wide availability and low cost of the AV, it is a sensible choice for reliable broadband digital communications on microgrid networks.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Power Delivery
Published
2024-11-11
DOI
https://doi.org/10.1109/tpwrd.2024.3488374
Citations
5
Primary Topic
Power Line Communications and Noise
Type
article
Field-Weighted Citation Impact
1.04
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Broadband Powerline Communication for Low-Voltage Microgrids

Derek Neal, Dan Rogers
5 citations
IEEE Transactions on Power Delivery
Power Line Communications and Noise
1.04
article

Broadband Powerline Communication for Low-Voltage Microgrids

Derek Neal, Dan Rogers
article en
5 citations

Abstract

The distributed-element transmission line model is modified to account for proximity effects in multiconductor cables and frequency dependent dielectric behaviour providing an accurate prediction of channel attenuation at broadband power line communication frequencies (1–100 MHz). The modified model is verified with scattering parameter measurements and then used as a building block for complex microgrid network modelling. Powerline communication performance tests are conducted using the HomePlug GreenPHY and HomePlug AV. The AV operates successfully up to 600 m on star feeders and on complex radial feeders in the presence of power converter noise. The GreenPHY operates up to 450 m on star feeders and on radial feeders with long branches. However, it cannot connect reliably on radial feeders with short branches due to frequency selective notching. Functionality requires link attenuation less than −60 dB at 30 MHz and the absence of notches that penetrate below −70 dB within the band (1.8–30 MHz). Due to the wide availability and low cost of the AV, it is a sensible choice for reliable broadband digital communications on microgrid networks.

IEEE Transactions on Power DeliveryVol. 40(1)
Oxford Research Group (GB), University of Oxford (GB)
Affordable and clean energy
Openalex Percentile: Top 22%
Power Line Communications and Noise
1.04
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.