Vitamin B12 Detection in Aqueous Media Using MPA-CdTe Quantum Dots

In this letter, we present a sensitive approach for the qualitative and quantitative detection of vitamin B12 (VB-12). The method utilizes dual-capped CdTe quantum dots (QDs) as a fluorescent probe. These QDs were synthesized through a one-pot synthesis method in an aqueous medium. Various factors affecting the accuracy of VB-12 determination were systematically investigated to establish optimal conditions. The resulting calibration curve, spanning the concentration range of 10–300 ng/mL of VB-12, exhibited a linear relationship, with a limit of detection and a limit of quantification of 0.326 ng/mL (0.3 nM), and 1.22 ng/mL, respectively. Additionally, the interaction mechanism responsible for the fluorescence quenching of CdTe QDs by VB-12 was discussed. The proposed method holds promise for sensitive and accurate VB-12 detection and may have applications in analytical chemistry and medical diagnostics.

Authors

Institutions

Publication Details

Journal
IEEE Sensors Letters
Published
2024-11-11
DOI
https://doi.org/10.1109/lsens.2024.3495512
Citations
1
Primary Topic
Advanced biosensing and bioanalysis techniques
Type
article
Field-Weighted Citation Impact
0.23
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Vitamin B12 Detection in Aqueous Media Using MPA-CdTe Quantum Dots

Bhavana Anchan, Suresh D. Kulkarni, Ajeetkumar Patil
1 citations
IEEE Sensors Letters
Advanced biosensing and bioanalysis techniques
0.23
article

Vitamin B12 Detection in Aqueous Media Using MPA-CdTe Quantum Dots

Bhavana Anchan, Suresh D. Kulkarni, Ajeetkumar Patil
article en
1 citations

Abstract

In this letter, we present a sensitive approach for the qualitative and quantitative detection of vitamin B12 (VB-12). The method utilizes dual-capped CdTe quantum dots (QDs) as a fluorescent probe. These QDs were synthesized through a one-pot synthesis method in an aqueous medium. Various factors affecting the accuracy of VB-12 determination were systematically investigated to establish optimal conditions. The resulting calibration curve, spanning the concentration range of 10–300 ng/mL of VB-12, exhibited a linear relationship, with a limit of detection and a limit of quantification of 0.326 ng/mL (0.3 nM), and 1.22 ng/mL, respectively. Additionally, the interaction mechanism responsible for the fluorescence quenching of CdTe QDs by VB-12 was discussed. The proposed method holds promise for sensitive and accurate VB-12 detection and may have applications in analytical chemistry and medical diagnostics.

IEEE Sensors LettersVol. 8(12)
Manipal Academy of Higher Education (IN)
Zero hunger
Openalex Percentile: Top 41%
Advanced biosensing and bioanalysis techniques
0.23
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.