Diagnostic accuracy and image quality evaluation of ultrashort echo time MRI in the lungs

This study evaluates the diagnostic accuracy of ultrashort echo time (UTE)-MRI for detecting pulmonary nodules and image quality. A total of 46 patients at our hospital underwent unenhanced computed tomography (CT) and UTE-MRI. The image quality and number of nodules detected using CT were used as the gold standards. Three diagnostic radiologists independently recorded the image quality (visibility and sharpness of normal anatomical structures) of the CT and UTE images and the number of pulmonary nodules detected. The diagnostic accuracy, subjective image quality, and consistency between observations were statistically analyzed. Among 46 patients, 36 (78.2%) had pulmonary nodules on CT images, whereas 10 patients (21.7%) had no pulmonary nodules. A total of 48 lung nodules were detected, 3 of which were ground-glass opacities. UTE-MRI revealed 46 lung nodules. Compared with CT, the sensitivity of all MRI readers for detecting lung lesions was 95.8%, and the 3-observer agreement was nearly perfect (P < .001, Kendall Wa [Kender Harmonious Coefficient] = 0.913). The overall image quality score of the observers was high, ranging from good to excellent, and the consistency of the subjective UTE-MRI image quality was good (Kendall Wa = 0.877, P < .001). For tracheal display, the subsegment of the bronchus was displayed, and the wall of the tube was clearly displayed. The difference in the Wa values between the observers was 0.804 (P < .001), indicating strong consistency. For blood vessels, subsegment blood vessels could also be displayed with clear walls and uniform signals (Kendal Wa = 0.823, P < .001), indicating strong consistency. Compared to CT, UTE-MRI can detect pulmonary nodules with a high detection rate, relatively good image quality, and strong consistency between observers. The development of UTE-MRI can provide a novel imaging method for the detection and follow-up of pulmonary nodules and diagnosis of pneumonia by reducing ionizing radiation.

Authors

Institutions

Publication Details

Journal
Medicine
Published
2024-11-08
DOI
https://doi.org/10.1097/md.0000000000040386
Citations
1
Primary Topic
Atomic and Subatomic Physics Research
Type
article
Field-Weighted Citation Impact
0.34
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Diagnostic accuracy and image quality evaluation of ultrashort echo time MRI in the lungs

Funan Wang, Liuhong Zhu, Xiaoxia Li, Chong Lin
1 citations
Medicine
Atomic and Subatomic Physics Research
0.34
article

Diagnostic accuracy and image quality evaluation of ultrashort echo time MRI in the lungs

Funan Wang, Liuhong Zhu, Xiaoxia Li, Chong Lin
article en
1 citations

Abstract

This study evaluates the diagnostic accuracy of ultrashort echo time (UTE)-MRI for detecting pulmonary nodules and image quality. A total of 46 patients at our hospital underwent unenhanced computed tomography (CT) and UTE-MRI. The image quality and number of nodules detected using CT were used as the gold standards. Three diagnostic radiologists independently recorded the image quality (visibility and sharpness of normal anatomical structures) of the CT and UTE images and the number of pulmonary nodules detected. The diagnostic accuracy, subjective image quality, and consistency between observations were statistically analyzed. Among 46 patients, 36 (78.2%) had pulmonary nodules on CT images, whereas 10 patients (21.7%) had no pulmonary nodules. A total of 48 lung nodules were detected, 3 of which were ground-glass opacities. UTE-MRI revealed 46 lung nodules. Compared with CT, the sensitivity of all MRI readers for detecting lung lesions was 95.8%, and the 3-observer agreement was nearly perfect (P < .001, Kendall Wa [Kender Harmonious Coefficient] = 0.913). The overall image quality score of the observers was high, ranging from good to excellent, and the consistency of the subjective UTE-MRI image quality was good (Kendall Wa = 0.877, P < .001). For tracheal display, the subsegment of the bronchus was displayed, and the wall of the tube was clearly displayed. The difference in the Wa values between the observers was 0.804 (P < .001), indicating strong consistency. For blood vessels, subsegment blood vessels could also be displayed with clear walls and uniform signals (Kendal Wa = 0.823, P < .001), indicating strong consistency. Compared to CT, UTE-MRI can detect pulmonary nodules with a high detection rate, relatively good image quality, and strong consistency between observers. The development of UTE-MRI can provide a novel imaging method for the detection and follow-up of pulmonary nodules and diagnosis of pneumonia by reducing ionizing radiation.

MedicineVol. 103(45)
Fudan University (CN), Zhongshan Hospital of Xiamen University (CN)
Good health and well-being
Openalex Percentile: Top 39%
Atomic and Subatomic Physics Research
0.34
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.