Feasibility of creating a daily adaptive plan using automatic DIR-created target and OARs contours in patients with prostate cancer magnetic-resonance-guided adaptive radiotherapy

The purpose of this study was to evaluate the feasibility of treatment plans for prostate cancer with magnetic resonance (MR)-guided online adaptive radiotherapy, which are generated using deformable image registration (DIR)-created contours of the targets and organs. Totally, 150 fractions from 30 prostate cancer patients implanted with a hydrogel spacer and treated with the MR-Linac were studied. Reference treatment plans that satisfied all institutional dose constraints were initially created on planning MRI. The adaptive treatment plans were created on daily MRI based on the reference plan using the DIR-created contours, ensuring all dose constraints were met. Subsequently, a clinician manually created reference contours for each daily MRI. Finally, the dose volume histogram indices of the plan generated with DIR-created contours were re-evaluated with clinician created contours. The evaluated contours included the bladder wall, rectum wall, sigmoid, small bowel and planning target volume (PTV) for dose prescription. The PTV for dose prescription met the dose constraints in all fractions. The bladder and rectum walls met the dose constraint of maximum dose (D0.03 cc) in all fractions. Five patients failed to meet the sigmoid and small bowel dose constraints, with the largest deviation being 13.3% exceedance at D2 cc in the small bowel added 3 mm margin. This study suggests that most treatment plans created without modifying the DIR-created contours are clinically viable. However, dislodgements of the small bowel and sigmoid may exceed the extent of DIR propagation from the reference plan contours, and it is recommended that these contours be verified.

Authors

Institutions

Publication Details

Journal
Journal of Radiation Research
Published
2024-11-01
DOI
https://doi.org/10.1093/jrr/rrae088
Citations
2
Primary Topic
Advanced Radiotherapy Techniques
Type
article
Field-Weighted Citation Impact
1.22
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Feasibility of creating a daily adaptive plan using automatic DIR-created target and OARs contours in patients with prostate cancer magnetic-resonance-guided adaptive radiotherapy

Takashi Uno, Makoto Saito, Masato Tsuneda, Yukinao Abe et al.
2 citations
Journal of Radiation Research
Advanced Radiotherapy Techniques
1.22
article

Feasibility of creating a daily adaptive plan using automatic DIR-created target and OARs contours in patients with prostate cancer magnetic-resonance-guided adaptive radiotherapy

Takashi Uno, Makoto Saito, Masato Tsuneda, Yukinao Abe, Miho Watanabe, Asuka Kodate, Aki Kanazawa, Kota Abe, Yukio Fujita, Rintaro Harada, Tsumugi Nishimura
article en
2 citations

Abstract

The purpose of this study was to evaluate the feasibility of treatment plans for prostate cancer with magnetic resonance (MR)-guided online adaptive radiotherapy, which are generated using deformable image registration (DIR)-created contours of the targets and organs. Totally, 150 fractions from 30 prostate cancer patients implanted with a hydrogel spacer and treated with the MR-Linac were studied. Reference treatment plans that satisfied all institutional dose constraints were initially created on planning MRI. The adaptive treatment plans were created on daily MRI based on the reference plan using the DIR-created contours, ensuring all dose constraints were met. Subsequently, a clinician manually created reference contours for each daily MRI. Finally, the dose volume histogram indices of the plan generated with DIR-created contours were re-evaluated with clinician created contours. The evaluated contours included the bladder wall, rectum wall, sigmoid, small bowel and planning target volume (PTV) for dose prescription. The PTV for dose prescription met the dose constraints in all fractions. The bladder and rectum walls met the dose constraint of maximum dose (D0.03 cc) in all fractions. Five patients failed to meet the sigmoid and small bowel dose constraints, with the largest deviation being 13.3% exceedance at D2 cc in the small bowel added 3 mm margin. This study suggests that most treatment plans created without modifying the DIR-created contours are clinically viable. However, dislodgements of the small bowel and sigmoid may exceed the extent of DIR propagation from the reference plan contours, and it is recommended that these contours be verified.

Journal of Radiation ResearchVol. 65(6)
Chiba University (JP), Chiba University Hospital (JP), Komazawa University (JP)
Good health and well-being
Openalex Percentile: Top 20%
Advanced Radiotherapy Techniques
1.22
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.