Study of magnetic field error suppression methods based on atomic parameters of cell in atomic co-magnetometer rotation measurement

Abstract We propose a new model for magnetic field errors based on the rotation measurement of the K-Rb- <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" overflow="scroll"> <mml:mrow> <mml:msup> <mml:mrow/> <mml:mrow> <mml:mn>21</mml:mn> </mml:mrow> </mml:msup> <mml:mtext>Ne</mml:mtext> </mml:mrow> </mml:math> co-magnetometer, considering the density ratio and spin collisions. The spin polarization characteristics of different alkali metal density ratios were analyzed by creating five cells with different density ratios, and the correctness of the magnetic field error model was verified experimentally. Moreover, the effects of five different alkali metal density ratios of cells on the sensitivity, long-term stability and magnetic field error suppression of the K-Rb- <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" overflow="scroll"> <mml:mrow> <mml:msup> <mml:mrow/> <mml:mrow> <mml:mn>21</mml:mn> </mml:mrow> </mml:msup> <mml:mtext>Ne</mml:mtext> </mml:mrow> </mml:math> co-magnetometer were investigated experimentally. When the density ratio is 1:107, there can be the optimal magnetic field error suppression effect, sensitivity and long-term stability. According to the derived magnetic field error equation, the magnetic noise error of the K-Rb- <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" overflow="scroll"> <mml:mrow> <mml:msup> <mml:mrow/> <mml:mrow> <mml:mn>21</mml:mn> </mml:mrow> </mml:msup> <mml:mtext>Ne</mml:mtext> </mml:mrow> </mml:math> co-magnetometer with an optimized density ratio is reduced by nearly 5 times from 260°/h/nT to 56.5°/h/nT, the sensitivity is improved from 2.9×10 −5 °/s/Hz <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" overflow="scroll"> <mml:mrow> <mml:msup> <mml:mrow/> <mml:mrow> <mml:mn>1</mml:mn> <mml:mo>/</mml:mo> <mml:mn>2</mml:mn> </mml:mrow> </mml:msup> </mml:mrow> </mml:math> to 7.0×10 −6 °/s/Hz <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" overflow="scroll"> <mml:mrow> <mml:msup> <mml:mrow/> <mml:mrow> <mml:mn>1</mml:mn> <mml:mo>/</mml:mo> <mml:mn>2</mml:mn> </mml:mrow> </mml:msup> </mml:mrow> </mml:math> at 1 Hz, and the long-term stability Allan variance over two hours is improved from 1.9×10 −2 °/h to 8.9×10 −3 °/h. This result provides a theoretical basis for designing the parameters of the K-Rb- <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" overflow="scroll"> <mml:mrow> <mml:msup> <mml:mrow/> <mml:mrow> <mml:mn>21</mml:mn> </mml:mrow> </mml:msup> <mml:mtext>Ne</mml:mtext> </mml:mrow> </mml:math> co-magnetometer cell.

Authors

Institutions

Publication Details

Journal
Measurement Science and Technology
Published
2024-11-11
DOI
https://doi.org/10.1088/1361-6501/ad90fd
Citations
9
Primary Topic
Atomic and Subatomic Physics Research
Type
article
Field-Weighted Citation Impact
3.04

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Study of magnetic field error suppression methods based on atomic parameters of cell in atomic co-magnetometer rotation measurement

Longyan Ma, Haoying Pang, Wenfeng Fan, Jiale Quan et al.
9 citations
Measurement Science and Technology
Atomic and Subatomic Physics Research
3.04
article

Study of magnetic field error suppression methods based on atomic parameters of cell in atomic co-magnetometer rotation measurement

Longyan Ma, Haoying Pang, Wenfeng Fan, Jiale Quan, Wei Quan, Shouzeng Zhou, Ye Liu, Yao Liu
article en
9 citations

Abstract

Abstract We propose a new model for magnetic field errors based on the rotation measurement of the K-Rb- <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" overflow="scroll"> <mml:mrow> <mml:msup> <mml:mrow/> <mml:mrow> <mml:mn>21</mml:mn> </mml:mrow> </mml:msup> <mml:mtext>Ne</mml:mtext> </mml:mrow> </mml:math> co-magnetometer, considering the density ratio and spin collisions. The spin polarization characteristics of different alkali metal density ratios were analyzed by creating five cells with different density ratios, and the correctness of the magnetic field error model was verified experimentally. Moreover, the effects of five different alkali metal density ratios of cells on the sensitivity, long-term stability and magnetic field error suppression of the K-Rb- <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" overflow="scroll"> <mml:mrow> <mml:msup> <mml:mrow/> <mml:mrow> <mml:mn>21</mml:mn> </mml:mrow> </mml:msup> <mml:mtext>Ne</mml:mtext> </mml:mrow> </mml:math> co-magnetometer were investigated experimentally. When the density ratio is 1:107, there can be the optimal magnetic field error suppression effect, sensitivity and long-term stability. According to the derived magnetic field error equation, the magnetic noise error of the K-Rb- <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" overflow="scroll"> <mml:mrow> <mml:msup> <mml:mrow/> <mml:mrow> <mml:mn>21</mml:mn> </mml:mrow> </mml:msup> <mml:mtext>Ne</mml:mtext> </mml:mrow> </mml:math> co-magnetometer with an optimized density ratio is reduced by nearly 5 times from 260°/h/nT to 56.5°/h/nT, the sensitivity is improved from 2.9×10 −5 °/s/Hz <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" overflow="scroll"> <mml:mrow> <mml:msup> <mml:mrow/> <mml:mrow> <mml:mn>1</mml:mn> <mml:mo>/</mml:mo> <mml:mn>2</mml:mn> </mml:mrow> </mml:msup> </mml:mrow> </mml:math> to 7.0×10 −6 °/s/Hz <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" overflow="scroll"> <mml:mrow> <mml:msup> <mml:mrow/> <mml:mrow> <mml:mn>1</mml:mn> <mml:mo>/</mml:mo> <mml:mn>2</mml:mn> </mml:mrow> </mml:msup> </mml:mrow> </mml:math> at 1 Hz, and the long-term stability Allan variance over two hours is improved from 1.9×10 −2 °/h to 8.9×10 −3 °/h. This result provides a theoretical basis for designing the parameters of the K-Rb- <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" overflow="scroll"> <mml:mrow> <mml:msup> <mml:mrow/> <mml:mrow> <mml:mn>21</mml:mn> </mml:mrow> </mml:msup> <mml:mtext>Ne</mml:mtext> </mml:mrow> </mml:math> co-magnetometer cell.

Measurement Science and TechnologyVol. 36(1)
Hefei University (CN), Zero Emissions Resource Organisation (NO), Extreme Light Infrastructure - Nuclear Physics (RO), Beihang University (CN)
National Natural Science Foundation of China, China Postdoctoral Science Foundation, National Science Fund for Distinguished Young Scholars
Openalex Percentile: Top 8%
Atomic and Subatomic Physics Research
3.04
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.