Radiation dose assessment during dental cone beam computed tomography procedures in Sri Lanka towards establishing a dose reference level

This study assesses radiation doses in cone beam computed tomography (CBCT) procedures in Sri Lanka, with the goal of establishing initial diagnostic reference levels (DRLs). Data from 1162 retrospective scans across four institutions were analyzed, and the medians of the pooled dose distribution for seven clinical indication categories were presented as the DRL values. The proposed DRLs based on clinical indications are 1013 mGy·cm2 for pathological conditions including cysts, tumors, and lesions, 1307 mGy·cm2 for implant planning, 1266 mGy·cm2 for presurgery assessment, and 1585 mGy·cm2 for evaluation of sinus and nasal pathology, temporomandibular disorder, and facial trauma. Considerable variability in doses across facilities was observed, driven by differences in equipment and imaging practices. Therefore, this study recommends adopting suggested DRL values as benchmarks, standardizing protocols to reduce dose variability, and implementing a national framework for regular updates of DRL values.

Authors

Institutions

Publication Details

Journal
Radiation Protection Dosimetry
Published
2024-11-11
DOI
https://doi.org/10.1093/rpd/ncae215
Citations
1
Primary Topic
Dental Radiography and Imaging
Type
article
Field-Weighted Citation Impact
0.49
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Radiation dose assessment during dental cone beam computed tomography procedures in Sri Lanka towards establishing a dose reference level

Jeyasingam Jeyasugiththan, W. R. U. A. Bandara, Nadeena Jayasuriya, Duminda Satharasinghe et al.
1 citations
Radiation Protection Dosimetry
Dental Radiography and Imaging
0.49
article

Radiation dose assessment during dental cone beam computed tomography procedures in Sri Lanka towards establishing a dose reference level

Jeyasingam Jeyasugiththan, W. R. U. A. Bandara, Nadeena Jayasuriya, Duminda Satharasinghe, Ruwan Duminda Jayasinghe, Indika Weerapperuma, M Nissanka, Wasundara Wijayasinghe
article en
1 citations

Abstract

This study assesses radiation doses in cone beam computed tomography (CBCT) procedures in Sri Lanka, with the goal of establishing initial diagnostic reference levels (DRLs). Data from 1162 retrospective scans across four institutions were analyzed, and the medians of the pooled dose distribution for seven clinical indication categories were presented as the DRL values. The proposed DRLs based on clinical indications are 1013 mGy·cm2 for pathological conditions including cysts, tumors, and lesions, 1307 mGy·cm2 for implant planning, 1266 mGy·cm2 for presurgery assessment, and 1585 mGy·cm2 for evaluation of sinus and nasal pathology, temporomandibular disorder, and facial trauma. Considerable variability in doses across facilities was observed, driven by differences in equipment and imaging practices. Therefore, this study recommends adopting suggested DRL values as benchmarks, standardizing protocols to reduce dose variability, and implementing a national framework for regular updates of DRL values.

Radiation Protection DosimetryVol. 201(1)
University of Peradeniya (LK), University of Manchester (GB), National Hospital of Sri Lanka (LK), University of Colombo (LK)
Good health and well-being
Openalex Percentile: Top 33%
Dental Radiography and Imaging
0.49
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.