Efficient low-cost design for high-frequency, accurate hardware implementation of cardiac Purkinje fiber cells for biomedical engineering approaches

Within the heart’s ventricle walls are where Purkinje fibers (PFs) are located. They are essential for maintaining a steady cardiac beat because they allow the heart’s conduction system to create synchronized contractions of its ventricles. To replicate or treat some of this organ’s ailments and deficits, hardware representation of the various heart sections is necessary. Models that include a series of differential equations can be used to characterize the performance of Purkinje Fibers (PFs) in Cardiac. To develop hardware that mimics the performance of PF of Cardiac system, the Noble model is updated in this study. Due to the requirement for using units like multipliers, the original model contains non-linear components that are slow and expensive in terms of hardware resources. The main novelty of revised model incorporates non-linear components that have been converted into two base-2 terms accompanied by additional factors. These calculations are executed through efficient and economical digital hardware, including logical shift operations, additions, and subtractions, enabling high-speed processing. To validate the precision and practicality of the suggested model, a digital platform, Virtex-7 FPGA, is employed. The findings demonstrate the suggested model’s simplicity of implementation on this board and its capability to generate various PF output patterns at a maximum frequency of 381.42 MHz. The proposed digital circuit can be applied in application-based fields according to high-speed, low-cost, and accurate design. Based on the high-switching speed of neural data transferring in the human brain, other organs that are realized on hardware platforms need to be designed in high-frequency (speed-up) for adaptation with the brain. Due to removing the non-linear terms, the modified model works 1.95 times faster than the original one and saves the FPGA resources up to 35%. In case of real-world applications, an efficient low-cost hardware design for high-frequency, accurate replication of cardiac Purkinje fiber cells has the potential to revolutionize the development of medical devices for diagnosing and treating cardiac conditions. The speed and cost-effectiveness of design make it particularly promising for the creation of advanced cardiac simulation and treatment systems. The high-speed, low-cost, and accurate hardware design has broader implications for biomedical engineering beyond the cardiac system. The ability to efficiently replicate the functions of biological systems using hardware could open doors for developing high-speed, low-cost, and accurate hardware models for simulating and understanding other biological processes, such as neural data processing in the human brain or the function of other vital organs.

Authors

Institutions

Publication Details

Journal
Engineering Science and Technology an International Journal
Published
2024-11-11
DOI
https://doi.org/10.1016/j.jestch.2024.101888
Citations
4
Primary Topic
Cardiac electrophysiology and arrhythmias
Type
article
Field-Weighted Citation Impact
1.61
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Efficient low-cost design for high-frequency, accurate hardware implementation of cardiac Purkinje fiber cells for biomedical engineering approaches

Guodao Zhang, Mohammad Sh. Daoud, Shuli Liu, B. -F. Ni et al.
4 citations
Engineering Science and Technology an International Journal
Cardiac electrophysiology and arrhythmias
1.61
article

Efficient low-cost design for high-frequency, accurate hardware implementation of cardiac Purkinje fiber cells for biomedical engineering approaches

Guodao Zhang, Mohammad Sh. Daoud, Shuli Liu, B. -F. Ni, Abdulilah Mohammad Mayet, Jun Sun, Yanhong Yang, Xinjun Miao, Xiaobo Wang
article en
4 citations

Abstract

Within the heart’s ventricle walls are where Purkinje fibers (PFs) are located. They are essential for maintaining a steady cardiac beat because they allow the heart’s conduction system to create synchronized contractions of its ventricles. To replicate or treat some of this organ’s ailments and deficits, hardware representation of the various heart sections is necessary. Models that include a series of differential equations can be used to characterize the performance of Purkinje Fibers (PFs) in Cardiac. To develop hardware that mimics the performance of PF of Cardiac system, the Noble model is updated in this study. Due to the requirement for using units like multipliers, the original model contains non-linear components that are slow and expensive in terms of hardware resources. The main novelty of revised model incorporates non-linear components that have been converted into two base-2 terms accompanied by additional factors. These calculations are executed through efficient and economical digital hardware, including logical shift operations, additions, and subtractions, enabling high-speed processing. To validate the precision and practicality of the suggested model, a digital platform, Virtex-7 FPGA, is employed. The findings demonstrate the suggested model’s simplicity of implementation on this board and its capability to generate various PF output patterns at a maximum frequency of 381.42 MHz. The proposed digital circuit can be applied in application-based fields according to high-speed, low-cost, and accurate design. Based on the high-switching speed of neural data transferring in the human brain, other organs that are realized on hardware platforms need to be designed in high-frequency (speed-up) for adaptation with the brain. Due to removing the non-linear terms, the modified model works 1.95 times faster than the original one and saves the FPGA resources up to 35%. In case of real-world applications, an efficient low-cost hardware design for high-frequency, accurate replication of cardiac Purkinje fiber cells has the potential to revolutionize the development of medical devices for diagnosing and treating cardiac conditions. The speed and cost-effectiveness of design make it particularly promising for the creation of advanced cardiac simulation and treatment systems. The high-speed, low-cost, and accurate hardware design has broader implications for biomedical engineering beyond the cardiac system. The ability to efficiently replicate the functions of biological systems using hardware could open doors for developing high-speed, low-cost, and accurate hardware models for simulating and understanding other biological processes, such as neural data processing in the human brain or the function of other vital organs.

Engineering Science and Technology an International JournalVol. 60
Tianjin University of Technology (CN), Al Ain University (AE), Wenzhou Medical University (CN), Wenzhou Central Hospital (CN), Hangzhou Dianzi University (CN), King Khalid University (SA)
Openalex Percentile: Top 14%
Cardiac electrophysiology and arrhythmias
1.61
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.