Ultrafast filtered back-projection for photoacoustic computed tomography

The filtered back-projection (FBP) algorithm is widely used in photoacoustic computed tomography (PACT) for image reconstruction due to its simplicity and efficiency. Yet, the real-time processing of high-speed PACT data remains challenging for regular FBP implementations. To enhance the reconstruction efficiency of the FBP algorithm, researchers have developed FBP implementations based on the graphics processing units (GPUs). However, existing GPU-accelerated FBP algorithms either sacrifice accuracy for efficiency or are still inefficient for high-speed, real-time PACT imaging. Herein, we report an ultrafast GPU acceleration-based FBP implementation for PACT image reconstruction without sacrificing accuracy. Firstly, the computation complexity of the filtering part of the FBP algorithm is significantly simplified with a pre-computed filtering matrix to enhance filtering efficiency. Secondly, the computation efficiency of the back-projection part of the FBP algorithm is dramatically increased through parallel programming and GPU acceleration. As a result, the proposed FBP implementation takes only 0.38 ms to reconstruct a two-dimensional image of 512 × 512 pixels, which is 439 times faster than regular FBP implementations. Numerical and experimental results show that the proposed FBP implementation outperforms existing GPU-based FBP implementations in reconstruction accuracy and computation efficiency. To the best of our knowledge, this is the fastest implementation of the FBP algorithm ever reported in PACT. This work is expected to provide an ultrafast and accurate image reconstruction solution for high-speed, real-time PACT imaging.

Authors

Institutions

Publication Details

Journal
Biomedical Optics Express
Published
2024-11-11
DOI
https://doi.org/10.1364/boe.540622
Citations
2
Primary Topic
Photoacoustic and Ultrasonic Imaging
Type
article
Field-Weighted Citation Impact
0.37

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Ultrafast filtered back-projection for photoacoustic computed tomography

Zhijian Tan, Songde Liu, Chao Tian, Sheng Wang et al.
2 citations
Biomedical Optics Express
Photoacoustic and Ultrasonic Imaging
0.37
article

Ultrafast filtered back-projection for photoacoustic computed tomography

Zhijian Tan, Songde Liu, Chao Tian, Sheng Wang, Pengfei Shao
article en
2 citations

Abstract

The filtered back-projection (FBP) algorithm is widely used in photoacoustic computed tomography (PACT) for image reconstruction due to its simplicity and efficiency. Yet, the real-time processing of high-speed PACT data remains challenging for regular FBP implementations. To enhance the reconstruction efficiency of the FBP algorithm, researchers have developed FBP implementations based on the graphics processing units (GPUs). However, existing GPU-accelerated FBP algorithms either sacrifice accuracy for efficiency or are still inefficient for high-speed, real-time PACT imaging. Herein, we report an ultrafast GPU acceleration-based FBP implementation for PACT image reconstruction without sacrificing accuracy. Firstly, the computation complexity of the filtering part of the FBP algorithm is significantly simplified with a pre-computed filtering matrix to enhance filtering efficiency. Secondly, the computation efficiency of the back-projection part of the FBP algorithm is dramatically increased through parallel programming and GPU acceleration. As a result, the proposed FBP implementation takes only 0.38 ms to reconstruct a two-dimensional image of 512 × 512 pixels, which is 439 times faster than regular FBP implementations. Numerical and experimental results show that the proposed FBP implementation outperforms existing GPU-based FBP implementations in reconstruction accuracy and computation efficiency. To the best of our knowledge, this is the fastest implementation of the FBP algorithm ever reported in PACT. This work is expected to provide an ultrafast and accurate image reconstruction solution for high-speed, real-time PACT imaging.

Biomedical Optics ExpressVol. 16(2)
University of Science and Technology of China (CN), Anhui University (CN), Anhui Medical University (CN), Institute of Art (PL), First Affiliated Hospital of Anhui Medical University (CN), National Science Centre (PL), Hefei First People's Hospital (CN)
National Natural Science Foundation of China, University of Science and Technology of China, Anhui Provincial Department of Science and Technology, Natural Science Foundation of Anhui Province, National Key Research and Development Program of China
Openalex Percentile: Top 42%
Photoacoustic and Ultrasonic Imaging
0.37
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.