A highly sensitive ratiometric optical thermometer based on a Sr<sub>2</sub>MgWO<sub>6</sub> double perovskite doped with Dy<sup>3+</sup> exploiting thermally coupled and uncoupled levels
The increasing demand for highly sensitive optical thermometers operating within a wide temperature range necessitates the development of new phosphors. In this work, the potential temperature sensing performance of a novel yellow-emitting phosphor, Sr<sub>2</sub>MgWO<sub>6</sub> double perovskite, doped with varying concentrations of Dy<sup>3+</sup> was investigated for the first time. Increasing the concentration of Dy<sup>3+</sup> from 0% to 7% shifted the color of luminescence from blue to yellowish-orange within the CIE1931 color space. The energy transfer efficiency from (WO<sub>6</sub>)<sup>6-</sup> to Dy<sup>3+</sup> also increased significantly to 98.4%. Moreover, the sample doped with 3% Dy<sup>3+</sup> showed the highest emission intensity, with a concentration beyond this threshold inducing concentration quenching. This phenomenon was primarily governed by dipole-dipole interactions. The highest quantum yield was found to be 30.7% for the sample doped with 3% Dy<sup>3+</sup>. Upon 266 nm wavelength excitation, the temperature sensing ability of the samples doped with 3%, 5%, and 7% Dy<sup>3+</sup> was examined based on the fluorescence intensity ratio between the thermally coupled and uncoupled levels. It showed that the relative thermal sensitivity of <i>S</i><sub>r</sub> can be tuned by changing the Dy<sup>3+</sup> concentration. <i>S</i><sub>r-max</sub> = 3.24% K<sup>-1</sup> was obtained for the sample doped with 3% Dy<sup>3+</sup> at 193 K within the 80-273 K operating range for thermally uncoupled levels. For thermally coupled levels, the <i>S</i><sub>r-max</sub> value reached 1.35% K<sup>-1</sup> at 333 K for the sample doped with 7% Dy<sup>3+</sup> in the range of 293-593 K. These results demonstrate the enormous potential of the studied materials for thermal sensing applications.
Authors
- Shovan Dan (ORCID: https://orcid.org/0000-0001-7763-2573)
- P.J. Dereń (ORCID: https://orcid.org/0000-0001-6316-6954)
- Bartosz Bondzior (ORCID: https://orcid.org/0000-0002-1764-2427)
- Thi Hong Quan Vu (ORCID: https://orcid.org/0000-0001-9390-3994)
- Dagmara Stefańska (ORCID: https://orcid.org/0000-0002-1051-3761)
Institutions
- Polish Academy of Sciences (PL)
Publication Details
- Journal
- Dalton Transactions
- Published
- 2024-11-11
- DOI
- https://doi.org/10.1039/d4dt02940b
- Citations
- 8
- Primary Topic
- Calibration and Measurement Techniques
- Type
- article
- Field-Weighted Citation Impact
- 10.39
Funders
- Narodowe Centrum Nauki