Broadband cavity-enhanced optical flux monitoring

This work describes a new type of sensor for growth process monitoring named broadband cavity-enhanced optical flux monitoring sensor (BBCE-OFM). Like existing optical flux monitoring (OFM) solutions, it relies on absorption spectroscopy. However, the implementation of an optical cavity reduces the measurement uncertainty, enabling efficient operation even at very low growth rates. Using the BBCE-OFM sensor mounted in our solid-source oxide molecular beam epitaxy reactor, we achieved an uncertainty of ±2% on the measurement of Sr and Ti growth rates in SrTiO3 at around 1 Ml/min, to be compared to the ±16% obtained in the same conditions using a conventional OFM setup. Furthermore, our sensor architecture, based on an echelle monochromator and LEDs replacing the hollow cathode lamps used in standard OFM sensors, is more robust against drift.

Authors

Institutions

Publication Details

Journal
Journal of Applied Physics
Published
2024-11-11
DOI
https://doi.org/10.1063/5.0235438
Primary Topic
Spectroscopy and Laser Applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Broadband cavity-enhanced optical flux monitoring

Roman Rousseau, Lotfi Berguiga, Guillaume Saint‐Girons, Romain Bachelet et al.
Journal of Applied Physics
Spectroscopy and Laser Applications
article

Broadband cavity-enhanced optical flux monitoring

Roman Rousseau, Lotfi Berguiga, Guillaume Saint‐Girons, Romain Bachelet, Clarisse Furgeaud, Jérôme Morville, Claude Botella, Mohamed Bounab
article en

Abstract

This work describes a new type of sensor for growth process monitoring named broadband cavity-enhanced optical flux monitoring sensor (BBCE-OFM). Like existing optical flux monitoring (OFM) solutions, it relies on absorption spectroscopy. However, the implementation of an optical cavity reduces the measurement uncertainty, enabling efficient operation even at very low growth rates. Using the BBCE-OFM sensor mounted in our solid-source oxide molecular beam epitaxy reactor, we achieved an uncertainty of ±2% on the measurement of Sr and Ti growth rates in SrTiO3 at around 1 Ml/min, to be compared to the ±16% obtained in the same conditions using a conventional OFM setup. Furthermore, our sensor architecture, based on an echelle monochromator and LEDs replacing the hollow cathode lamps used in standard OFM sensors, is more robust against drift.

Journal of Applied PhysicsVol. 136(18)
Université Claude Bernard Lyon 1 (FR), École Centrale de Lyon (FR), Centre National de la Recherche Scientifique (FR), Institut des Nanotechnologies de Lyon (FR)
Agence Nationale de la Recherche
Affordable and clean energy
Openalex Percentile: Top 85%
Spectroscopy and Laser Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.