Implementation of Bond’s Scheme in a Single Crystal Diffractometer. Study of the Homogeneity of (Y1–xEux)2O3 Single Crystals

An original procedure is proposed to refine unit cell parameters (UCPs) of single crystals in Bond’s scheme. The procedure involves the use of a modern laboratory diffractometer equipped with a 2D detector and a three-circle goniometer. At the first stage, preliminary UCPs, diffraction class, and crystal orientation relative to goniometer axes are determined. Then φ and ω angles are calculated to bring an appropriate (occurrence of a well-resolved doublet, intensity) reflection hkl on the equatorial plane. The measurement in Bond’s scheme is carried out at two symmetric positions of the detector ±2θD ≈ 2θhkl. The principal difference from the measurement on a single crystal spectrometer consists in refusing to plot the reflection profile I(ω) and passing to ω-scans with a width of 3-4°, which allows the measurement of the Kα1/Kα2 doublet profile. After its processing by two independent 2D functions, coordinates of the maxima are determined, and then the 4θhkl. Angle is found based on angular sizes of the detector pixel and the difference in the coordinates of X Kα1-component reflections obtained in symmetric positions. In this approach, measurement errors are related to the accuracy of placing the detector in two symmetric positions and the correctness of processing 2D reflection profiles. In the study of reference Si and Ge single crystals in the range of 2θD angles close to 100°, UCP deviations from the theoretical values are found to not exceed 0.0004 Å, and the relative measurement accuracy is 6·10–5. The refinement of UCPs of single crystals grown in the Y2O3–Eu2O3 system by the melt-solution technique indicates the formation of the (Y1–xEux)2O3 solid solution with the x value range of 0.27-0.40. A scheme is proposed to improve the measurement accuracy when the procedure is transferred to the diffractometer with synchrotron radiation.

Authors

Institutions

Publication Details

Journal
Journal of Structural Chemistry
Published
2024-10-01
DOI
https://doi.org/10.1134/s0022476624100056
Citations
5
Primary Topic
X-ray Diffraction in Crystallography
Type
article
Field-Weighted Citation Impact
0.59
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Implementation of Bond’s Scheme in a Single Crystal Diffractometer. Study of the Homogeneity of (Y1–xEux)2O3 Single Crystals

Н.Г. Наумов, S. А. Gromilov, P. S. Serebrennikova, A. L. Kudryavtsev
5 citations
Journal of Structural Chemistry
X-ray Diffraction in Crystallography
0.59
article

Implementation of Bond’s Scheme in a Single Crystal Diffractometer. Study of the Homogeneity of (Y1–xEux)2O3 Single Crystals

Н.Г. Наумов, S. А. Gromilov, P. S. Serebrennikova, A. L. Kudryavtsev
article en
5 citations

Abstract

An original procedure is proposed to refine unit cell parameters (UCPs) of single crystals in Bond’s scheme. The procedure involves the use of a modern laboratory diffractometer equipped with a 2D detector and a three-circle goniometer. At the first stage, preliminary UCPs, diffraction class, and crystal orientation relative to goniometer axes are determined. Then φ and ω angles are calculated to bring an appropriate (occurrence of a well-resolved doublet, intensity) reflection hkl on the equatorial plane. The measurement in Bond’s scheme is carried out at two symmetric positions of the detector ±2θD ≈ 2θhkl. The principal difference from the measurement on a single crystal spectrometer consists in refusing to plot the reflection profile I(ω) and passing to ω-scans with a width of 3-4°, which allows the measurement of the Kα1/Kα2 doublet profile. After its processing by two independent 2D functions, coordinates of the maxima are determined, and then the 4θhkl. Angle is found based on angular sizes of the detector pixel and the difference in the coordinates of X Kα1-component reflections obtained in symmetric positions. In this approach, measurement errors are related to the accuracy of placing the detector in two symmetric positions and the correctness of processing 2D reflection profiles. In the study of reference Si and Ge single crystals in the range of 2θD angles close to 100°, UCP deviations from the theoretical values are found to not exceed 0.0004 Å, and the relative measurement accuracy is 6·10–5. The refinement of UCPs of single crystals grown in the Y2O3–Eu2O3 system by the melt-solution technique indicates the formation of the (Y1–xEux)2O3 solid solution with the x value range of 0.27-0.40. A scheme is proposed to improve the measurement accuracy when the procedure is transferred to the diffractometer with synchrotron radiation.

Journal of Structural ChemistryVol. 65(10)
Novosibirsk State University (RU), Nikolaev Institute of Inorganic Chemistry (RU)
Openalex Percentile: Top 33%
X-ray Diffraction in Crystallography
0.59
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.