BEST PRACTICE UNTUK OPTIMISASI DAN KESELAMATAN RADIASI DI RUANGAN KATETERISASI KARDIOVASKULAR (CATHLAB) RS SENTRA MEDIKA CIBINONG

Scattered radiation generated during fluoroscopy increases the potential for patients and staff to receive radiation doses, so it is necessary to take optimization steps for radiation safety to minimize the risk of exposure to scattered X-ray radiation. This study aims to implement radiation protection in cardiac and vascular catheterization laboratories and summarize best practices for implementing efforts to minimize radiation exposure. The method used was qualitative and quantitative from 2023 to 2024; with this qualitative approach, the supervision activities in TLD badges for radiation workers, the level of diagnostic guidance for patients, and the use of radiation protection equipment were observed. For the quantitative approach, measuring the dose rate was carried out, and optimizing the positioning of the distance between the patient's table and the radiation source was carried out by direct measurement. Based on research data, the observation results obtained that the apron is still by the minimum thickness, which is 0.35-0.5 mm Pb for intervention, the results of exposure tests around the cathlab room are around 0.08-0.12 μSv/hour still below the dose constraint value, Mapping the rate of exposure in the work area during the intervention procedure obtained an optimal safe distance of around 60-70 cm from the X-ray tube. The setup of the effective distance position for intervention patients is at a distance of 80 cm from the X-ray tube to the patient table, which can reduce the absorbed dose to the patient by around 30%, the use of low dose mode (7.5 fps) with pulsed fluoroscopy during the intervention obtained the absorbed dose received by the patient reduced by 70-72% for PCI procedures and 25-29% for the type of CAG procedure. It is hoped that the protocol that uses this best practice can minimize the risk of exposure to scattered radiation and optimize medical exposure. Keywords: cathlab, best practices radiation protection, dose rate, radiation exposure, patient radiation dose.

Authors

Publication Details

Journal
Prosiding Seminar Si-INTAN
Published
2024-11-06
DOI
https://doi.org/10.53862/ssi.v4.092024.008
Primary Topic
Public Health and Nutrition
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

BEST PRACTICE UNTUK OPTIMISASI DAN KESELAMATAN RADIASI DI RUANGAN KATETERISASI KARDIOVASKULAR (CATHLAB) RS SENTRA MEDIKA CIBINONG

Habib Syeh Alzufri, Dede Nurmiati
Prosiding Seminar Si-INTAN
Public Health and Nutrition
article

BEST PRACTICE UNTUK OPTIMISASI DAN KESELAMATAN RADIASI DI RUANGAN KATETERISASI KARDIOVASKULAR (CATHLAB) RS SENTRA MEDIKA CIBINONG

Habib Syeh Alzufri, Dede Nurmiati
article en

Abstract

Scattered radiation generated during fluoroscopy increases the potential for patients and staff to receive radiation doses, so it is necessary to take optimization steps for radiation safety to minimize the risk of exposure to scattered X-ray radiation. This study aims to implement radiation protection in cardiac and vascular catheterization laboratories and summarize best practices for implementing efforts to minimize radiation exposure. The method used was qualitative and quantitative from 2023 to 2024; with this qualitative approach, the supervision activities in TLD badges for radiation workers, the level of diagnostic guidance for patients, and the use of radiation protection equipment were observed. For the quantitative approach, measuring the dose rate was carried out, and optimizing the positioning of the distance between the patient's table and the radiation source was carried out by direct measurement. Based on research data, the observation results obtained that the apron is still by the minimum thickness, which is 0.35-0.5 mm Pb for intervention, the results of exposure tests around the cathlab room are around 0.08-0.12 μSv/hour still below the dose constraint value, Mapping the rate of exposure in the work area during the intervention procedure obtained an optimal safe distance of around 60-70 cm from the X-ray tube. The setup of the effective distance position for intervention patients is at a distance of 80 cm from the X-ray tube to the patient table, which can reduce the absorbed dose to the patient by around 30%, the use of low dose mode (7.5 fps) with pulsed fluoroscopy during the intervention obtained the absorbed dose received by the patient reduced by 70-72% for PCI procedures and 25-29% for the type of CAG procedure. It is hoped that the protocol that uses this best practice can minimize the risk of exposure to scattered radiation and optimize medical exposure. Keywords: cathlab, best practices radiation protection, dose rate, radiation exposure, patient radiation dose.

Prosiding Seminar Si-INTANVol. 4(1)
Good health and well-being
Openalex Percentile: Top 69%
Public Health and Nutrition
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

BEST PRACTICE UNTUK OPTIMISASI DAN KESELAMATAN RADIASI DI RUANGAN KATETERISASI KARDIOVASKULAR (CATHLAB) RS SENTRA MEDIKA CIBINONG — Habib Syeh Alzufri, Dede Nurmiati · Prosiding Seminar Si-INTAN (2024) | TGRS Research Map | TGRS