OPTIMISASI PROTEKSI RADIASI PADA PASIEN MELALUI IMPLEMENTASI DIAGNOSTIC REFERENCE LEVEL (DRL) LOKAL PADA PEMERIKSAAN DENTAL PANORAMIC DI INSTALASI RADIOLOGI RSUD PROF. DR. MARGONO SOEKARJO

One of the principles of radiation protection is optimization. Optimization is done to make the dose received as low as reasonably achievable (ALARA) by considering economic and social factors. Implementation of radiation protection optimization can be done with dose management through the Local Diagnostic Reference Level (DRL). In recent years, the Nuclear Energy Regulatory Agency (BAPETEN) has set the Indonesian DRL value for several X-ray modalities, including dental panoramic. This study was motivated by panoramic patient dose audit data using the auto mode exposure factor, which operators often use. The method for determining the manual mode exposure factor is carried out by comparing the image quality of the current variations of 6.3 mA, 8 mA, 10 mA, 13 mA, and 16 mA with a fixed voltage of 66 kV and a time of 14.1 seconds. The local DRL value was obtained by comparing the dental panoramic auto mode measurements with manual mode using certain exposure factors according to the recommendations in the initial study using a head phantom. This study used 100 patient data with adult human criteria aged over 15. The results obtained from the initial study and questionnaires in manual mode were the values that had the highest CNR and SNR at a current variation of 10 mA. The exposure factor was then used to collect patient data. The local DRL value obtained for auto mode was 83.35 mGy cm2; in manual mode, it was 57.7 mGy cm2. Manual mode exposure factors in dental panoramic examinations affected the implementation of local DRL values with a decrease of 30.77% from auto mode. The use of manual mode in dental panoramic examinations significantly reduces the radiation dose received by patients, so the use of manual mode is one of the steps to optimize radiation protection. Keywords: Diagnostic Reference Level (DRL), optimization of radiation protection in patients, dental panoramic.

Authors

Publication Details

Journal
Prosiding Seminar Si-INTAN
Published
2024-11-06
DOI
https://doi.org/10.53862/ssi.v4.092024.006
Primary Topic
Dental Radiography and Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

OPTIMISASI PROTEKSI RADIASI PADA PASIEN MELALUI IMPLEMENTASI DIAGNOSTIC REFERENCE LEVEL (DRL) LOKAL PADA PEMERIKSAAN DENTAL PANORAMIC DI INSTALASI RADIOLOGI RSUD PROF. DR. MARGONO SOEKARJO

Dita Kusumaningrum, Hening Fitra Dewi, Etmy Kurniasari, Fathul Jannah
Prosiding Seminar Si-INTAN
Dental Radiography and Imaging
article

OPTIMISASI PROTEKSI RADIASI PADA PASIEN MELALUI IMPLEMENTASI DIAGNOSTIC REFERENCE LEVEL (DRL) LOKAL PADA PEMERIKSAAN DENTAL PANORAMIC DI INSTALASI RADIOLOGI RSUD PROF. DR. MARGONO SOEKARJO

Dita Kusumaningrum, Hening Fitra Dewi, Etmy Kurniasari, Fathul Jannah
article en

Abstract

One of the principles of radiation protection is optimization. Optimization is done to make the dose received as low as reasonably achievable (ALARA) by considering economic and social factors. Implementation of radiation protection optimization can be done with dose management through the Local Diagnostic Reference Level (DRL). In recent years, the Nuclear Energy Regulatory Agency (BAPETEN) has set the Indonesian DRL value for several X-ray modalities, including dental panoramic. This study was motivated by panoramic patient dose audit data using the auto mode exposure factor, which operators often use. The method for determining the manual mode exposure factor is carried out by comparing the image quality of the current variations of 6.3 mA, 8 mA, 10 mA, 13 mA, and 16 mA with a fixed voltage of 66 kV and a time of 14.1 seconds. The local DRL value was obtained by comparing the dental panoramic auto mode measurements with manual mode using certain exposure factors according to the recommendations in the initial study using a head phantom. This study used 100 patient data with adult human criteria aged over 15. The results obtained from the initial study and questionnaires in manual mode were the values that had the highest CNR and SNR at a current variation of 10 mA. The exposure factor was then used to collect patient data. The local DRL value obtained for auto mode was 83.35 mGy cm2; in manual mode, it was 57.7 mGy cm2. Manual mode exposure factors in dental panoramic examinations affected the implementation of local DRL values with a decrease of 30.77% from auto mode. The use of manual mode in dental panoramic examinations significantly reduces the radiation dose received by patients, so the use of manual mode is one of the steps to optimize radiation protection. Keywords: Diagnostic Reference Level (DRL), optimization of radiation protection in patients, dental panoramic.

Prosiding Seminar Si-INTANVol. 4(1)
Affordable and clean energy
Openalex Percentile: Top 70%
Dental Radiography and Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

OPTIMISASI PROTEKSI RADIASI PADA PASIEN MELALUI IMPLEMENTASI DIAGNOSTIC REFERENCE LEVEL (DRL) LOKAL PADA PEMERIKSAAN DENTAL PANORAMIC DI INSTALASI RADIOLOGI RSUD PROF. DR. MARGONO SOEKARJO — Dita Kusumaningrum, Hening Fitra Dewi, et al. · Prosiding Seminar Si-INTAN (2024) | TGRS Research Map | TGRS