Application of random quality control based on time -series model in ELISA detection of blood donors in Nanjing

This study introduces a completely Random Quality Control (R-QC) method for Enzyme-Linked Immunosorbent Assay (ELISA) tests and compares it with traditional Fixed Quality Control (F-QC) methods across different testing items. A random quality control system was constructed using a Time-series model, enabling fully random positioning of quality control in ELISA tests. The Coefficient of Variation (CV) for R-QC were found to be lower as compared to F-QC in Hepatitis B surface antigen (HBsAg), anti-Human Immunodeficiency Virus (anti-HIV), and Treponema Pallidum (TP) items, and there were significant differences among them. Moreover, the alarm rates and out of control rates in the R-QC groups were notably lower than those in the F-QC groups. The experimentally designed R-QC method demonstrates superior stability, reducing alarm and out of control rates, with has significant implications for improving ELISA testing at the Nanjing Blood Center.

Authors

Publication Details

Journal
Heliyon
Published
2024-11-01
DOI
https://doi.org/10.1016/j.heliyon.2024.e40317
Primary Topic
Hepatitis B Virus Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Application of random quality control based on time -series model in ELISA detection of blood donors in Nanjing

P. Hu, Runmin Dong, Libo Zhang, Jingjing Bao et al.
Heliyon
Hepatitis B Virus Studies
article

Application of random quality control based on time -series model in ELISA detection of blood donors in Nanjing

P. Hu, Runmin Dong, Libo Zhang, Jingjing Bao, Rongrong Pang, Wenping Han, Cheng‐Ping Ma, Yang Liu
article en

Abstract

This study introduces a completely Random Quality Control (R-QC) method for Enzyme-Linked Immunosorbent Assay (ELISA) tests and compares it with traditional Fixed Quality Control (F-QC) methods across different testing items. A random quality control system was constructed using a Time-series model, enabling fully random positioning of quality control in ELISA tests. The Coefficient of Variation (CV) for R-QC were found to be lower as compared to F-QC in Hepatitis B surface antigen (HBsAg), anti-Human Immunodeficiency Virus (anti-HIV), and Treponema Pallidum (TP) items, and there were significant differences among them. Moreover, the alarm rates and out of control rates in the R-QC groups were notably lower than those in the F-QC groups. The experimentally designed R-QC method demonstrates superior stability, reducing alarm and out of control rates, with has significant implications for improving ELISA testing at the Nanjing Blood Center.

HeliyonVol. 10(22)
Good health and well-being
Openalex Percentile: Top 70%
Hepatitis B Virus Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Application of random quality control based on time -series model in ELISA detection of blood donors in Nanjing — P. Hu, Runmin Dong, et al. · Heliyon (2024) | TGRS Research Map | TGRS