Cardiopulmonary exercise testing in aortic stenosis patients before and after aortic valve replacement

Median peak workload increased by 8% from 133 (55) watts at PRE to 144 (67) watts at POST (p<0.001). Median ventilatory threshold (VO<sub>2</sub>@VT) increased from 1216 (391) to 1328 (309) mL/min (p=0.001, n=28). Mean peak oxygen uptake (peakVO<sub>2</sub>) was not significantly different between PRE and POST; 1871±441 vs 1937±404 mL/min (p=0.08). The oxygen uptake efficacy slope (OUES) was significantly correlated to PeakVO2 at both PRE (r=0.889, p<0.05) and POST (r=0.888, p<0.05) CONCLUSION: Physical work capacity was improved 1 year following sAVR, in terms of higher median peak workload and VO<sub>2</sub>@VT. The strong correlation between the submaximal variable OUES and peakVO<sub>2</sub> suggests that OUES might be a useful surrogate of peakVO<sub>2</sub> in this group of patients where maximal exercise testing is not always recommended.

Authors

Institutions

Publication Details

Journal
Open Heart
Published
2024-11-01
DOI
https://doi.org/10.1136/openhrt-2024-002786
Citations
2
Primary Topic
Cardiac Valve Diseases and Treatments
Type
article
Field-Weighted Citation Impact
0.80
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Cardiopulmonary exercise testing in aortic stenosis patients before and after aortic valve replacement

Eva Nylander, Éva Tamás, Carl Bellander, H. Nilsson et al.
2 citations
Open Heart
Cardiac Valve Diseases and Treatments
0.80
article

Cardiopulmonary exercise testing in aortic stenosis patients before and after aortic valve replacement

Eva Nylander, Éva Tamás, Carl Bellander, H. Nilsson, Kristofer Hedman
article en
2 citations

Abstract

Median peak workload increased by 8% from 133 (55) watts at PRE to 144 (67) watts at POST (p<0.001). Median ventilatory threshold (VO<sub>2</sub>@VT) increased from 1216 (391) to 1328 (309) mL/min (p=0.001, n=28). Mean peak oxygen uptake (peakVO<sub>2</sub>) was not significantly different between PRE and POST; 1871±441 vs 1937±404 mL/min (p=0.08). The oxygen uptake efficacy slope (OUES) was significantly correlated to PeakVO2 at both PRE (r=0.889, p<0.05) and POST (r=0.888, p<0.05) CONCLUSION: Physical work capacity was improved 1 year following sAVR, in terms of higher median peak workload and VO<sub>2</sub>@VT. The strong correlation between the submaximal variable OUES and peakVO<sub>2</sub> suggests that OUES might be a useful surrogate of peakVO<sub>2</sub> in this group of patients where maximal exercise testing is not always recommended.

Open HeartVol. 11(2)
Linköping University (SE), Linköping University Hospital (SE)
Good health and well-being
Openalex Percentile: Top 23%
Cardiac Valve Diseases and Treatments
0.80
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Cardiopulmonary exercise testing in aortic stenosis patients before and after aortic valve replacement — Eva Nylander, Éva Tamás, et al. · Open Heart (2024) | TGRS Research Map | TGRS