Experimental study of ventilation performance of three ventilation strategies using aerosols and tracer gas

• The clean air flow rate varies according to the position at which it is measured. • A mixed ventilation system is more efficient with CO 2 than with particles. • Particle efficacy in worker inhaled volume increased with personal exhaust system. • Personal exhaust system had not effect on intake fraction of healthcare worker using CO 2 . Effective ventilation plays a crucial role in reducing the risk of infection by airborne contaminants. This study was conducted in a hospital ward of specific dimensions (41.58 m 3 ) equipped with two respiratory thermal manikins: a healthcare worker and an infected patient. Three ventilation strategies were employed in the ventilation system: supply and exhaust air through upper grilles, upper and lower grilles, and swirl diffusers with lower grilles. The air flow rate of the ventilation system was maintained constant at 200 m 3 /h. The airflow was distributed 50-50% by a combination of a personalised ventilation system and personalised exhaust system. The effectiveness of a ventilation system and its combination with a personalised exhaust system was investigated using aerosol and tracer gas techniques. The efficacy of contaminant removal was evaluated in both the patient and healthcare inhaled volume. Determination of the clean air flow rate of the three ventilation system strategies at inhaled volume was carried out. Also, the exposure of healthcare worker to the contaminants exhaled by infected patient in the microenvironment formed by both was analysed. Experimental findings revealed that CO 2 showed a higher ventilation efficiency compared to particles, independently of the ventilation strategy used. The highest clean air flow rate values were detected in the inhaled volume of patient infected. On the other hand, the highest particle removal efficiency was observed in swirl diffusers with lower grilles, which combined the ventilation system with the PES. This strategy also showed the lowest exposure values in the microenvironment.

Authors

Institutions

Publication Details

Journal
Results in Engineering
Published
2024-11-08
DOI
https://doi.org/10.1016/j.rineng.2024.103380
Citations
1
Primary Topic
Infection Control and Ventilation
Type
article
Field-Weighted Citation Impact
0.42

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Experimental study of ventilation performance of three ventilation strategies using aerosols and tracer gas

Manuel Ruiz de Adana, José Luis Sánchez Jiménez
1 citations
Results in Engineering
Infection Control and Ventilation
0.42
article

Experimental study of ventilation performance of three ventilation strategies using aerosols and tracer gas

Manuel Ruiz de Adana, José Luis Sánchez Jiménez
article en
1 citations

Abstract

• The clean air flow rate varies according to the position at which it is measured. • A mixed ventilation system is more efficient with CO 2 than with particles. • Particle efficacy in worker inhaled volume increased with personal exhaust system. • Personal exhaust system had not effect on intake fraction of healthcare worker using CO 2 . Effective ventilation plays a crucial role in reducing the risk of infection by airborne contaminants. This study was conducted in a hospital ward of specific dimensions (41.58 m 3 ) equipped with two respiratory thermal manikins: a healthcare worker and an infected patient. Three ventilation strategies were employed in the ventilation system: supply and exhaust air through upper grilles, upper and lower grilles, and swirl diffusers with lower grilles. The air flow rate of the ventilation system was maintained constant at 200 m 3 /h. The airflow was distributed 50-50% by a combination of a personalised ventilation system and personalised exhaust system. The effectiveness of a ventilation system and its combination with a personalised exhaust system was investigated using aerosol and tracer gas techniques. The efficacy of contaminant removal was evaluated in both the patient and healthcare inhaled volume. Determination of the clean air flow rate of the three ventilation system strategies at inhaled volume was carried out. Also, the exposure of healthcare worker to the contaminants exhaled by infected patient in the microenvironment formed by both was analysed. Experimental findings revealed that CO 2 showed a higher ventilation efficiency compared to particles, independently of the ventilation strategy used. The highest clean air flow rate values were detected in the inhaled volume of patient infected. On the other hand, the highest particle removal efficiency was observed in swirl diffusers with lower grilles, which combined the ventilation system with the PES. This strategy also showed the lowest exposure values in the microenvironment.

Results in EngineeringVol. 24
University of Córdoba (ES)
Ministerio de Ciencia, Innovación y Universidades, Ministerio de Ciencia e Innovación, European Regional Development Fund
Affordable and clean energy
Openalex Percentile: Top 31%
Infection Control and Ventilation
0.42
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.