High‐Resolution X‐Ray Imaging With 0D Organic–Metal Halide Scintillator Featuring Reversed Exciton Trapping

Abstract Scintillators, essential for applications in nuclear medicine, radiation detection, and industrial inspection, convert high‐energy radiation into visible light. Manganese (Mn)‐based inorganic–organic hybrid materials are distinguished by their thermal stability, mechanical strength, and flexibility. However, the effects of temperature on Mn(II)‐based hybrid scintillators have not been clearly analyzed, making the elucidation of their temperature‐dependent luminescence mechanisms particularly important. A notable advancement is the synthesis of Mn‐ 1 nanocrystals (NCs) using methyltriphenylphosphonium chloride (mtppCl) and MnCl₂. These NCs exhibit distinctive temperature‐dependent photoluminescence luminescence: the intensity decreases from 77 to 150 K but paradoxically increases at higher temperatures due to anomalous thermal exciton behavior in the [MnCl₄] 2 ⁻ tetrahedra. Besides, Mn‐ 1 NCs achieve a detection limit of 1.01 µGy air /s, surpassing medical diagnostic standards and outperforming commercial scintillators such as Bi₄Ge₃O₁₂ (BGO). Additionally, they show exceptional stability under continuous irradiation and can be incorporated into a flexible scintillating film with a resolution of 11.3 lp/mm at an MTF of 0.2. The current study has further refined the luminescence mechanism of Mn(II)‐based materials and optimizes their properties for a wider range of applications.

Authors

Institutions

Publication Details

Journal
Laser & Photonics Review
Published
2024-11-07
DOI
https://doi.org/10.1002/lpor.202401342
Citations
24
Primary Topic
Medical Imaging Techniques and Applications
Type
article
Field-Weighted Citation Impact
9.70

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

High‐Resolution X‐Ray Imaging With 0D Organic–Metal Halide Scintillator Featuring Reversed Exciton Trapping

Meng Cui, Baoyi Li, Jian Lü, Shuai‐Hua Wang et al.
24 citations
Laser & Photonics Review
Medical Imaging Techniques and Applications
9.70
article

High‐Resolution X‐Ray Imaging With 0D Organic–Metal Halide Scintillator Featuring Reversed Exciton Trapping

Meng Cui, Baoyi Li, Jian Lü, Shuai‐Hua Wang, Fa‐Kun Zheng, Guo‐Cong Guo, Peng‐Kun Wang, Rui‐Xuan Qian
article en
24 citations

Abstract

Abstract Scintillators, essential for applications in nuclear medicine, radiation detection, and industrial inspection, convert high‐energy radiation into visible light. Manganese (Mn)‐based inorganic–organic hybrid materials are distinguished by their thermal stability, mechanical strength, and flexibility. However, the effects of temperature on Mn(II)‐based hybrid scintillators have not been clearly analyzed, making the elucidation of their temperature‐dependent luminescence mechanisms particularly important. A notable advancement is the synthesis of Mn‐ 1 nanocrystals (NCs) using methyltriphenylphosphonium chloride (mtppCl) and MnCl₂. These NCs exhibit distinctive temperature‐dependent photoluminescence luminescence: the intensity decreases from 77 to 150 K but paradoxically increases at higher temperatures due to anomalous thermal exciton behavior in the [MnCl₄] 2 ⁻ tetrahedra. Besides, Mn‐ 1 NCs achieve a detection limit of 1.01 µGy air /s, surpassing medical diagnostic standards and outperforming commercial scintillators such as Bi₄Ge₃O₁₂ (BGO). Additionally, they show exceptional stability under continuous irradiation and can be incorporated into a flexible scintillating film with a resolution of 11.3 lp/mm at an MTF of 0.2. The current study has further refined the luminescence mechanism of Mn(II)‐based materials and optimizes their properties for a wider range of applications.

Laser & Photonics ReviewVol. 19(4)
Fujian Normal University (CN), Chinese Academy of Sciences (CN), Fujian Institute of Research on the Structure of Matter (CN), Tan Kah Kee Innovation Laboratory (CN), University of Chinese Academy of Sciences (CN)
National Natural Science Foundation of China
Affordable and clean energy
Openalex Percentile: Top 1%
Medical Imaging Techniques and Applications
9.70
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.