Post-burn and post-blast rapid detection of trace and bulk energetics by 3D-printed cone spray ionization mass spectrometry

• 3D-Printed Cone Spray Ionization Mass Spectrometry (3D-PCSI-MS) Analysis. • Rapid Trace and Bulk Detection of Energetics by 3D-PCSI-MS. • Post-Blast and Post-Burn Material Analysis. • Analysis of Military Grade and Homemade Explosives. • Coupling of 3D-PCSI-MS to a Field Portable Mass Spectrometer. Forensic analysis of post-blast and post-burn materials can be critical to a law enforcement or military investigation. 3D-printed cone spray ionization (3D-PCSI) coupled to a field portable mass spectrometer (MS) has been demonstrated as a rapid and low-cost alternative to traditional laboratory-based techniques (high resolution liquid or gas chromatography mass spectrometry) for the detection and analysis of energetic materials. 3D-PCSI-MS can sample trace or bulk energetics within or upon solid matrices with no sample preparation. Solid samples, in this case post-blast or post-burn energetics, are placed within the hollow cavity of the cone that has an approximately 100 µm spray-based emitter at the apex. An extraction/spray solvent is added, and a high voltage is subsequently applied. When coupled to a field portable MS, post-burn and post-blast analyses can be performed in the field. Double base propellant was burned on a variety of substrates and examined via 3D-PCSI-MS. An energetic material and stabilizers used in propellants were detected from the post-burn samples with no sample preparation. Trinitrotoluene (TNT, used in military and commercial explosives) and triacetone triperoxide (TATP, a homemade explosive) were examined post-blast on the US ton scale and the gram scale, respectively.

Authors

Institutions

Publication Details

Journal
Talanta Open
Published
2024-11-08
DOI
https://doi.org/10.1016/j.talo.2024.100377
Citations
6
Primary Topic
Mass Spectrometry Techniques and Applications
Type
article
Field-Weighted Citation Impact
1.44
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Post-burn and post-blast rapid detection of trace and bulk energetics by 3D-printed cone spray ionization mass spectrometry

Patrick W. Fedick, Ryan M. Bain, Christopher C. Mulligan, TJ Pinedo et al.
6 citations
Talanta Open
Mass Spectrometry Techniques and Applications
1.44
article

Post-burn and post-blast rapid detection of trace and bulk energetics by 3D-printed cone spray ionization mass spectrometry

Patrick W. Fedick, Ryan M. Bain, Christopher C. Mulligan, TJ Pinedo, Doug J. Klapec
article en
6 citations

Abstract

• 3D-Printed Cone Spray Ionization Mass Spectrometry (3D-PCSI-MS) Analysis. • Rapid Trace and Bulk Detection of Energetics by 3D-PCSI-MS. • Post-Blast and Post-Burn Material Analysis. • Analysis of Military Grade and Homemade Explosives. • Coupling of 3D-PCSI-MS to a Field Portable Mass Spectrometer. Forensic analysis of post-blast and post-burn materials can be critical to a law enforcement or military investigation. 3D-printed cone spray ionization (3D-PCSI) coupled to a field portable mass spectrometer (MS) has been demonstrated as a rapid and low-cost alternative to traditional laboratory-based techniques (high resolution liquid or gas chromatography mass spectrometry) for the detection and analysis of energetic materials. 3D-PCSI-MS can sample trace or bulk energetics within or upon solid matrices with no sample preparation. Solid samples, in this case post-blast or post-burn energetics, are placed within the hollow cavity of the cone that has an approximately 100 µm spray-based emitter at the apex. An extraction/spray solvent is added, and a high voltage is subsequently applied. When coupled to a field portable MS, post-burn and post-blast analyses can be performed in the field. Double base propellant was burned on a variety of substrates and examined via 3D-PCSI-MS. An energetic material and stabilizers used in propellants were detected from the post-burn samples with no sample preparation. Trinitrotoluene (TNT, used in military and commercial explosives) and triacetone triperoxide (TATP, a homemade explosive) were examined post-blast on the US ton scale and the gram scale, respectively.

Talanta OpenVol. 10
United States Department of Justice (US), Naval Air Systems Command (US), Naval Air Warfare Center Weapons Division (US), Illinois State University (US)
Affordable and clean energy
Openalex Percentile: Top 19%
Mass Spectrometry Techniques and Applications
1.44
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.