Wavelet Phase Coherence Analysis of Oxyhemoglobin and DeoxyHemoglobin Oscillations to Investigate the Relationship Between Cups of Cupping Therapy

Research has not demonstrated whether multiple cups of negative pressure cupping therapy would induce interactions of hemodynamic responses between different areas. A multichannel near-infrared spectroscopy (NIRS) was used to assess oxyhemoglobin and deoxyhemoglobin oscillations in response to cupping therapy. Wavelet transform and wavelet phase (WPC) coherence were used to quantify NIRS signals. Three levels of negative pressure (-75, -225, and -300 mmHg) were applied to the gastrocnemius in 12 healthy adults. Oxyhemoglobin coherence between the two inside-cup areas was higher at -75 mmHg compared to -300 mmHg in both metabolic (WPC = 0.80 ± 0.11 vs. 0.73 ± 0.13) and neurogenic (WPC = 0.70 ± 0.11 vs. 0.60 ± 0.17) controls. Deoxyhemoglobin coherence was also higher at -75 mmHg compared to -300 mmHg in both metabolic (WPC = 0.78 ± 0.11 vs. 0.66 ± 0.14) and neurogenic (WPC = 0.67 ± 0.11 vs. 0.58 ± 0.13) controls. Our study provides first evidence on the interaction of hemodynamic responses between the two cups of cupping therapy using WPC analysis of NIRS signals.

Authors

Institutions

Publication Details

Journal
Journal of Biophotonics
Published
2024-11-08
DOI
https://doi.org/10.1002/jbio.202400337
Citations
3
Primary Topic
Heart Rate Variability and Autonomic Control
Type
article
Field-Weighted Citation Impact
1.21
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Wavelet Phase Coherence Analysis of Oxyhemoglobin and DeoxyHemoglobin Oscillations to Investigate the Relationship Between Cups of Cupping Therapy

Hongjun Yu, Manuel E. Hernandez, Pu‐Chun Mo, Yih‐Kuen Jan et al.
3 citations
Journal of Biophotonics
Heart Rate Variability and Autonomic Control
1.21
article

Wavelet Phase Coherence Analysis of Oxyhemoglobin and DeoxyHemoglobin Oscillations to Investigate the Relationship Between Cups of Cupping Therapy

Hongjun Yu, Manuel E. Hernandez, Pu‐Chun Mo, Yih‐Kuen Jan, Weicheng Shen, Liwan Huang, Mansoureh Samadi
article en
3 citations

Abstract

Research has not demonstrated whether multiple cups of negative pressure cupping therapy would induce interactions of hemodynamic responses between different areas. A multichannel near-infrared spectroscopy (NIRS) was used to assess oxyhemoglobin and deoxyhemoglobin oscillations in response to cupping therapy. Wavelet transform and wavelet phase (WPC) coherence were used to quantify NIRS signals. Three levels of negative pressure (-75, -225, and -300 mmHg) were applied to the gastrocnemius in 12 healthy adults. Oxyhemoglobin coherence between the two inside-cup areas was higher at -75 mmHg compared to -300 mmHg in both metabolic (WPC = 0.80 ± 0.11 vs. 0.73 ± 0.13) and neurogenic (WPC = 0.70 ± 0.11 vs. 0.60 ± 0.17) controls. Deoxyhemoglobin coherence was also higher at -75 mmHg compared to -300 mmHg in both metabolic (WPC = 0.78 ± 0.11 vs. 0.66 ± 0.14) and neurogenic (WPC = 0.67 ± 0.11 vs. 0.58 ± 0.13) controls. Our study provides first evidence on the interaction of hemodynamic responses between the two cups of cupping therapy using WPC analysis of NIRS signals.

Journal of BiophotonicsVol. 18(1)
Asia University (TW), University of Illinois Urbana-Champaign (US), Tsinghua University (CN)
Openalex Percentile: Top 18%
Heart Rate Variability and Autonomic Control
1.21
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.