An In-Depth Analysis of Peritoneal Dialysate Effluent Composition with a Deep-UV-LED-Based Affordable Optical Chromatographic Sensor

It was shown earlier that the use of fast protein and metabolites liquid chromatography (FPMLC) and low-cost deep UV–LED-based optical chromatographic sensors with PD-10 desalting columns as a separation element can facilitate the monitoring of patients on chronic peritoneal dialysis (PD). Previously, we established that the first peak in the FPMLC chromatograms of effluent dialysate is mainly responsible for proteins and could be used for the assessment of peritoneal protein loss in patients on PD, while the origin and clinical significance of the other two peaks still remain unclear. Optical absorption and fluorescence spectroscopy in the UV and visible regions of 240…720 nm were used for the analysis of PD effluent chromatographic fractions collected from a drainpipe of the sensor with photometric detection at 280 nm; chromatograms of twenty dialysate samples were processed. The absorption and fluorescence spectra of the first fraction demonstrated peaks at 270 nm and 330 nm, respectively, which is typical for proteins. The absorption spectra of the third fraction revealed the characteristic maxima of creatinine and uric acid, while the fluorescence spectra showed the characteristic peak of indoxyl sulfate 375 nm at 270 nm excitation. The second fraction had a single, extremely wide absorption band, strong fluorescence was observed at 440–450 nm while excited at 370 nm. Such spectral characteristics are typical for advanced glycation end products (AGE). Thus, it was demonstrated that deep UV–LED-based affordable chromatographic sensors could provide significantly more information about the composition of PD effluent dialysate than just the total protein concentration, including the contents of clinically significant metabolites, e.g., indoxyl sulfate and AGE. Moreover, the introduction of optical fluorescence detection could significantly improve the capabilities of such devices.

Authors

Institutions

Publication Details

Published
2024-11-07
DOI
https://doi.org/10.3390/engproc2024073008
Citations
1
Primary Topic
Biosensors and Analytical Detection
Type
article
Field-Weighted Citation Impact
0.18
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

An In-Depth Analysis of Peritoneal Dialysate Effluent Composition with a Deep-UV-LED-Based Affordable Optical Chromatographic Sensor

Aleksandr Frorip, N. A. Ovsyannikov, Зарина Рустамова, Роман Герасимчук et al.
1 citations
Biosensors and Analytical Detection
0.18
article

An In-Depth Analysis of Peritoneal Dialysate Effluent Composition with a Deep-UV-LED-Based Affordable Optical Chromatographic Sensor

Aleksandr Frorip, N. A. Ovsyannikov, Зарина Рустамова, Роман Герасимчук, Alar Sünter, Георгий Коноплев, Vadim Korsakov, Oksana Stepanova, Artur Kuznetsov, Алина Исачкина, Milana Mikhailis
article en
1 citations

Abstract

It was shown earlier that the use of fast protein and metabolites liquid chromatography (FPMLC) and low-cost deep UV–LED-based optical chromatographic sensors with PD-10 desalting columns as a separation element can facilitate the monitoring of patients on chronic peritoneal dialysis (PD). Previously, we established that the first peak in the FPMLC chromatograms of effluent dialysate is mainly responsible for proteins and could be used for the assessment of peritoneal protein loss in patients on PD, while the origin and clinical significance of the other two peaks still remain unclear. Optical absorption and fluorescence spectroscopy in the UV and visible regions of 240…720 nm were used for the analysis of PD effluent chromatographic fractions collected from a drainpipe of the sensor with photometric detection at 280 nm; chromatograms of twenty dialysate samples were processed. The absorption and fluorescence spectra of the first fraction demonstrated peaks at 270 nm and 330 nm, respectively, which is typical for proteins. The absorption spectra of the third fraction revealed the characteristic maxima of creatinine and uric acid, while the fluorescence spectra showed the characteristic peak of indoxyl sulfate 375 nm at 270 nm excitation. The second fraction had a single, extremely wide absorption band, strong fluorescence was observed at 440–450 nm while excited at 370 nm. Such spectral characteristics are typical for advanced glycation end products (AGE). Thus, it was demonstrated that deep UV–LED-based affordable chromatographic sensors could provide significantly more information about the composition of PD effluent dialysate than just the total protein concentration, including the contents of clinically significant metabolites, e.g., indoxyl sulfate and AGE. Moreover, the introduction of optical fluorescence detection could significantly improve the capabilities of such devices.

Estonian University of Life Sciences (EE), Saint Petersburg State Electrotechnical University (RU), St. Petersburg State Health Care Foundation "Mariinsky City Hospital" (RU), North-Western State Medical University named after I.I. Mechnikov (RU)
Clean water and sanitation
Openalex Percentile: Top 51%
Biosensors and Analytical Detection
0.18
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.