Effects of Different Inhibitors on the Corrosion Mitigation of Steel Rebar Immersed in NaCl-Contaminated Concrete Pore Solution

The corrosion of steel rebar embedded in concrete under marine conditions is a major global concern. Therefore, it needs a proper corrosion mitigation method. Various types of corrosion inhibitors are used to mitigate the corrosion of steel rebar in chloride-contaminated concrete; however, selecting the appropriate inhibitor and determining its optimal concentration remains a concern. Therefore, in the present study, three types of inhibitors—calcium nitrite (CN: Ca(NO2)2), N,N′-dimethyl ethanol amine (DMEA: (CH3)2NCH2CH2OH), and L-arginine (LA: C6H14N4O2) in three different concentrations, i.e., 0.3, 0.6 and 1.2 M—were compared with a control (without inhibitor, i.e., blank) sample to determine the optimum concentration of the inhibitor for corrosion resistance performance evaluation of reinforcement bars immersed in 0.3 M NaCl-contaminated concrete pore (NCCP) solution for various durations. The corrosion resistance properties were assessed using open circuit potential (OCP), electrochemical impedance spectroscopy (EIS) with immersion duration, and potentiodynamic polarization (PDP) after 168 h of exposure. The results showed that the CN inhibitor performed exceptionally well (corrosion inhibition efficiency greater than 97%) in terms of corrosion resistance. However, due to its hazardous nature and its ban in the U.S. and European Union, CN cannot be used in construction. In comparison, while DMEA showed some effectiveness, LA performed better and is also eco-friendly. The corrosion resistance efficiency of samples containing 0.6 M LA remains above 97% even after 168 h of immersion in the NCCP solution. This efficiency is consistent throughout the entire immersion period, from 1 h to 168 h. Therefore, it is recommended that LA be used as a corrosion inhibitor for steel reinforcement bars instead of CN, particularly in chloride-contaminated concrete, as it is both effective and safer than CN.

Authors

Institutions

Publication Details

Journal
Buildings
Published
2024-11-07
DOI
https://doi.org/10.3390/buildings14113559
Citations
4
Primary Topic
Concrete Corrosion and Durability
Type
article
Field-Weighted Citation Impact
1.04
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effects of Different Inhibitors on the Corrosion Mitigation of Steel Rebar Immersed in NaCl-Contaminated Concrete Pore Solution

Han‐Seung Lee, Jitendra Kumar Singh, Sang-Ho Min
4 citations
Buildings
Concrete Corrosion and Durability
1.04
article

Effects of Different Inhibitors on the Corrosion Mitigation of Steel Rebar Immersed in NaCl-Contaminated Concrete Pore Solution

Han‐Seung Lee, Jitendra Kumar Singh, Sang-Ho Min
article en
4 citations

Abstract

The corrosion of steel rebar embedded in concrete under marine conditions is a major global concern. Therefore, it needs a proper corrosion mitigation method. Various types of corrosion inhibitors are used to mitigate the corrosion of steel rebar in chloride-contaminated concrete; however, selecting the appropriate inhibitor and determining its optimal concentration remains a concern. Therefore, in the present study, three types of inhibitors—calcium nitrite (CN: Ca(NO2)2), N,N′-dimethyl ethanol amine (DMEA: (CH3)2NCH2CH2OH), and L-arginine (LA: C6H14N4O2) in three different concentrations, i.e., 0.3, 0.6 and 1.2 M—were compared with a control (without inhibitor, i.e., blank) sample to determine the optimum concentration of the inhibitor for corrosion resistance performance evaluation of reinforcement bars immersed in 0.3 M NaCl-contaminated concrete pore (NCCP) solution for various durations. The corrosion resistance properties were assessed using open circuit potential (OCP), electrochemical impedance spectroscopy (EIS) with immersion duration, and potentiodynamic polarization (PDP) after 168 h of exposure. The results showed that the CN inhibitor performed exceptionally well (corrosion inhibition efficiency greater than 97%) in terms of corrosion resistance. However, due to its hazardous nature and its ban in the U.S. and European Union, CN cannot be used in construction. In comparison, while DMEA showed some effectiveness, LA performed better and is also eco-friendly. The corrosion resistance efficiency of samples containing 0.6 M LA remains above 97% even after 168 h of immersion in the NCCP solution. This efficiency is consistent throughout the entire immersion period, from 1 h to 168 h. Therefore, it is recommended that LA be used as a corrosion inhibitor for steel reinforcement bars instead of CN, particularly in chloride-contaminated concrete, as it is both effective and safer than CN.

BuildingsVol. 14(11)
Hanyang University (KR), Graphic Era University (IN)
Life below water
Openalex Percentile: Top 25%
Concrete Corrosion and Durability
1.04
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.