Uncertainties of S-Parameter Measurements in Rectangular Waveguides at PTB

Abstract. In this work the determination of measurement uncertainties in scattering parameter measurements for waveguide interfaces ranging from R 100 (WR 90) to R 2.6k (WR 3, WM-864) is presented. For each waveguide band a Thru Reflect Line calibration is performed including uncertainties for calibration standards, cable movement, interface repeatability and the characteristics of the vector network analyzer. For reflection and transmission coefficients, envelopes of uncertainties are determined for magnitude and phase angle respectively. In addition, an experiment on connection (interface) repeatability for R 140 was carried out to systematically investigate the influence of shifting and rotating of waveguide flanges. Translation values in steps of 0.3 mm up to 1.5 mm are examined in simulation as well as measurement. The findings of these investigations can be extended and applied to other waveguide bands.

Authors

Institutions

Publication Details

Journal
Advances in radio science
Published
2024-11-08
DOI
https://doi.org/10.5194/ars-22-35-2024
Citations
2
Primary Topic
Microwave and Dielectric Measurement Techniques
Type
article
Field-Weighted Citation Impact
0.42
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Uncertainties of S-Parameter Measurements in Rectangular Waveguides at PTB

Karsten Kuhlmann, Frauke Gellersen, Andreas Schramm
2 citations
Advances in radio science
Microwave and Dielectric Measurement Techniques
0.42
article

Uncertainties of S-Parameter Measurements in Rectangular Waveguides at PTB

Karsten Kuhlmann, Frauke Gellersen, Andreas Schramm
article en
2 citations

Abstract

Abstract. In this work the determination of measurement uncertainties in scattering parameter measurements for waveguide interfaces ranging from R 100 (WR 90) to R 2.6k (WR 3, WM-864) is presented. For each waveguide band a Thru Reflect Line calibration is performed including uncertainties for calibration standards, cable movement, interface repeatability and the characteristics of the vector network analyzer. For reflection and transmission coefficients, envelopes of uncertainties are determined for magnitude and phase angle respectively. In addition, an experiment on connection (interface) repeatability for R 140 was carried out to systematically investigate the influence of shifting and rotating of waveguide flanges. Translation values in steps of 0.3 mm up to 1.5 mm are examined in simulation as well as measurement. The findings of these investigations can be extended and applied to other waveguide bands.

Advances in radio scienceVol. 22
Physikalisch-Technische Bundesanstalt (DE)
Openalex Percentile: Top 37%
Microwave and Dielectric Measurement Techniques
0.42
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.