Colistin, Meropenem–Vaborbactam, Imipenem–Relebactam, and Eravacycline Testing in Carbapenem-Resistant Gram-Negative Rods: A Comparative Evaluation of Broth Microdilution, Gradient Test, and VITEK 2

We observed substantial variability in the measured MICs between BMD and the alternative methods. In only a few constellations, VITEK 2 or gradient tests could substitute the reference method. BMD is the method of choice for COL analysis, with VITEK 2 representing an alternative method for CRPA testing. Alternative methods for MVB did not provide reliable results, except for Enterobacterales, when tested with the gradient test. However, resistant results need to be confirmed by BMD. Only BMD can be used for IRL MIC determination. VITEK 2 was mostly accurate in measuring ERV MICs, while the corresponding gradient test yielded reliable results exclusively in CREs. It is essential that laboratories are aware of which testing method provides reliable results for each combination of microorganisms and reserve antibiotics.

Authors

Institutions

Publication Details

Journal
Antibiotics
Published
2024-11-08
DOI
https://doi.org/10.3390/antibiotics13111062
Citations
2
Primary Topic
Antibiotic Resistance in Bacteria
Type
article
Field-Weighted Citation Impact
0.34
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Colistin, Meropenem–Vaborbactam, Imipenem–Relebactam, and Eravacycline Testing in Carbapenem-Resistant Gram-Negative Rods: A Comparative Evaluation of Broth Microdilution, Gradient Test, and VITEK 2

Josefa Luxner, Karl Dichtl, Lea Fuchs, Andrea Grisold et al.
2 citations
Antibiotics
Antibiotic Resistance in Bacteria
0.34
article

Colistin, Meropenem–Vaborbactam, Imipenem–Relebactam, and Eravacycline Testing in Carbapenem-Resistant Gram-Negative Rods: A Comparative Evaluation of Broth Microdilution, Gradient Test, and VITEK 2

Josefa Luxner, Karl Dichtl, Lea Fuchs, Andrea Grisold, Ivo Steinmetz, Patrick Forstner
article en
2 citations

Abstract

We observed substantial variability in the measured MICs between BMD and the alternative methods. In only a few constellations, VITEK 2 or gradient tests could substitute the reference method. BMD is the method of choice for COL analysis, with VITEK 2 representing an alternative method for CRPA testing. Alternative methods for MVB did not provide reliable results, except for Enterobacterales, when tested with the gradient test. However, resistant results need to be confirmed by BMD. Only BMD can be used for IRL MIC determination. VITEK 2 was mostly accurate in measuring ERV MICs, while the corresponding gradient test yielded reliable results exclusively in CREs. It is essential that laboratories are aware of which testing method provides reliable results for each combination of microorganisms and reserve antibiotics.

AntibioticsVol. 13(11)
Medical University of Graz (AT)
Openalex Percentile: Top 46%
Antibiotic Resistance in Bacteria
0.34
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.