Development of a Sensitive Cysteine-Modified Au-NPs–Graphene Nanoribbons Nanocomposite Disposable Biosensor for Aflatoxin B1 Detection in Food samples

A simple and sensitive electrochemical biosensor based on a disposable graphite pencil electrode (PGE) is proposed for the detection of aflatoxin B1 (AFB1) in food samples. The biosensor utilized graphene nanoribbons (GNRs)–gold nanoparticles (Au-NPs) nanocomposites as the sensing material, with cysteine (Cys) and antiaflatoxin B1 (anti-AFB1) antibody serving as the detection probe. GNRs were produced by the oxidative unzipping of multiwalled carbon nanotubes (MWCNTs), followed by the electrodeposition of Au-NPs on GNRs-modified PGE and surface modification with Cys. Various characterization techniques were employed to analyze the MWCNTs, confirm the formation of GNRs, and verify the GNRs–Au-NPs nanocomposite. Electrochemical methods, including cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS), were used to characterize each step of the biosensor fabrication. EIS was initially applied to test the designed biosensor for detecting AFB1 in phosphate-buffered saline (PBS) and later in spiked maize samples containing varying concentrations of the target analyte. The biosensor response was validated by using CV and differential pulse voltammetry (DPV). The biosensor demonstrated a good linear response over the investigated concentration range, with a limit of detection (LOD) of 0.06 ng mL–1, improved selectivity, higher repeatability, and stable performance over 24 days. Additionally, the sensor exhibited a good percent recovery when detecting AFB1 in spiked maize samples.

Authors

Institutions

Publication Details

Journal
ACS Applied Nano Materials
Published
2024-11-08
DOI
https://doi.org/10.1021/acsanm.4c04764
Citations
13
Primary Topic
Advanced biosensing and bioanalysis techniques
Type
article
Field-Weighted Citation Impact
3.04

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development of a Sensitive Cysteine-Modified Au-NPs–Graphene Nanoribbons Nanocomposite Disposable Biosensor for Aflatoxin B1 Detection in Food samples

Ayaz Hassan, Rizwan Wahab, Muhammad Farooq, Adil Ijaz et al.
13 citations
ACS Applied Nano Materials
Advanced biosensing and bioanalysis techniques
3.04
article

Development of a Sensitive Cysteine-Modified Au-NPs–Graphene Nanoribbons Nanocomposite Disposable Biosensor for Aflatoxin B1 Detection in Food samples

Ayaz Hassan, Rizwan Wahab, Muhammad Farooq, Adil Ijaz, Akhtar Hayat, Muhammad Hammad Aziz, Ayesha Muhaddas
article en
13 citations

Abstract

A simple and sensitive electrochemical biosensor based on a disposable graphite pencil electrode (PGE) is proposed for the detection of aflatoxin B1 (AFB1) in food samples. The biosensor utilized graphene nanoribbons (GNRs)–gold nanoparticles (Au-NPs) nanocomposites as the sensing material, with cysteine (Cys) and antiaflatoxin B1 (anti-AFB1) antibody serving as the detection probe. GNRs were produced by the oxidative unzipping of multiwalled carbon nanotubes (MWCNTs), followed by the electrodeposition of Au-NPs on GNRs-modified PGE and surface modification with Cys. Various characterization techniques were employed to analyze the MWCNTs, confirm the formation of GNRs, and verify the GNRs–Au-NPs nanocomposite. Electrochemical methods, including cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS), were used to characterize each step of the biosensor fabrication. EIS was initially applied to test the designed biosensor for detecting AFB1 in phosphate-buffered saline (PBS) and later in spiked maize samples containing varying concentrations of the target analyte. The biosensor response was validated by using CV and differential pulse voltammetry (DPV). The biosensor demonstrated a good linear response over the investigated concentration range, with a limit of detection (LOD) of 0.06 ng mL–1, improved selectivity, higher repeatability, and stable performance over 24 days. Additionally, the sensor exhibited a good percent recovery when detecting AFB1 in spiked maize samples.

ACS Applied Nano MaterialsVol. 7(22)
COMSATS University Islamabad (PK), Chinese Academy of Sciences (CN), King Saud University (SA), Hefei Institutes of Physical Science (CN), Institute of Intelligent Machines (CN)
Ministry of Science and Technology, Pakistan, King Saud University
Openalex Percentile: Top 8%
Advanced biosensing and bioanalysis techniques
3.04
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.