Autonomous Vibrationless Temperature-Controlled Cryosystem for Optical Studies with a Spectroscopic Ellipsometer

Introduction. Ellipsometry is a highly sensitive, non-destructive optical method used to study the optical and structural properties of materials and thin films.Problem Statement. At the Institute of Semiconductor Physics of the National Academy of Sciences of Ukraine, the first in Ukraine serial spectroscopic ellipsometer SE-2000 (manufactured by SEMILAB Ltd., Hungary) has been employed for research, but its measurement capabilities are currently limited to room temperature.Purpose. This research aims to expand the functionality of the SE-2000 by creating a temperature-controlled cryosystem that operates within a temperature range from –195 оC to +80 оC (approximately 80—353 K).Materials and Methods. An autonomous, precision, vibrationless, cryosystem has been designed and manufactured for low-temperature optical investigations in reflection mode, based on a gas-flow cryostat. The cryosystem includes a cryostat, a microprocessor temperature controller, and an adjustment table.Results. The cryostat operates on a gas-flow principle. A laminar gas flow is generated by excess pressure achieved through the heating of cryogenic liquid by a heater-evaporator in the feeder tank. The flow intensity is regulated by adjusting the power supplied to the heating element, eliminating vibrations in the cryostat and sample. The heat exchange chamber is positioned at the top of the nitrogen tank, with the test sample mounted in horizontal plane. Incident and reflected light beams interact with the sample from the upper hemisphere. Sample positioning is adjustable via translational motion along three Cartesian coordinates and by tilting the cryostat with the help of the adjustment table.Conclusions. This system is suitable for use in optical devices that operate in specular reflection mode, with access to the sample surface from the upper hemisphere.

Authors

Institutions

Publication Details

Journal
Science and innovation
Published
2024-11-07
DOI
https://doi.org/10.15407/scine20.06.018
Primary Topic
Photonic and Optical Devices
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Autonomous Vibrationless Temperature-Controlled Cryosystem for Optical Studies with a Spectroscopic Ellipsometer

А. Солонецький, V. R. Romanyuk, I.P. Palamarchuk, S.V. Mamykin et al.
Science and innovation
Photonic and Optical Devices
article

Autonomous Vibrationless Temperature-Controlled Cryosystem for Optical Studies with a Spectroscopic Ellipsometer

А. Солонецький, V. R. Romanyuk, I.P. Palamarchuk, S.V. Mamykin, O.V. Selivanov, I.P. Zharkov, V.M. Konoval, O. Yastrubchak, V.A. Khodunov, V.V. Safronov
article en

Abstract

Introduction. Ellipsometry is a highly sensitive, non-destructive optical method used to study the optical and structural properties of materials and thin films.Problem Statement. At the Institute of Semiconductor Physics of the National Academy of Sciences of Ukraine, the first in Ukraine serial spectroscopic ellipsometer SE-2000 (manufactured by SEMILAB Ltd., Hungary) has been employed for research, but its measurement capabilities are currently limited to room temperature.Purpose. This research aims to expand the functionality of the SE-2000 by creating a temperature-controlled cryosystem that operates within a temperature range from –195 оC to +80 оC (approximately 80—353 K).Materials and Methods. An autonomous, precision, vibrationless, cryosystem has been designed and manufactured for low-temperature optical investigations in reflection mode, based on a gas-flow cryostat. The cryosystem includes a cryostat, a microprocessor temperature controller, and an adjustment table.Results. The cryostat operates on a gas-flow principle. A laminar gas flow is generated by excess pressure achieved through the heating of cryogenic liquid by a heater-evaporator in the feeder tank. The flow intensity is regulated by adjusting the power supplied to the heating element, eliminating vibrations in the cryostat and sample. The heat exchange chamber is positioned at the top of the nitrogen tank, with the test sample mounted in horizontal plane. Incident and reflected light beams interact with the sample from the upper hemisphere. Sample positioning is adjustable via translational motion along three Cartesian coordinates and by tilting the cryostat with the help of the adjustment table.Conclusions. This system is suitable for use in optical devices that operate in specular reflection mode, with access to the sample surface from the upper hemisphere.

Science and innovationVol. 20(6)
V.E. Lashkaryov Institute of Semiconductor Physics (UA), Institute of Physics (UA)
Openalex Percentile: Top 82%
Photonic and Optical Devices
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.