Abandoned guidewire recapture from aortic root using “Guidewire twirling technique”

Percutaneous coronary intervention (PCI) is a common procedure for treating coronary artery disease, but it can be complicated by the loss and fracture of coronary guidewires within the vascular system, leading to severe complications such as vessel damage, occlusion, and embolization. This case report describes a unique and challenging scenario involving an 81-year-old male patient who, during an elective coronary angiography, was found to have a fractured and partially decoiled coronary guidewire extending from the aortic root to the left subclavian artery. The guidewire had likely been left in place during a previous procedure and was not documented in the patient's medical history. Given the potential for life-threatening complications, including occlusion of the left internal mammary artery graft, a percutaneous retrieval was attempted. Initial efforts using a snare system were unsuccessful. However, the guidewire was successfully retrieved using the “twirling guidewires” technique, which involved entangling the fractured wire with three 0.014-inch guidewires and carefully extracting it through a guide catheter. The patient avoided invasive surgery and was discharged without complications the day after. This case highlights the importance of recognizing and managing lost guidewire fragments using various percutaneous techniques, underscoring the need for interventional cardiologists to be adept in both coronary and peripheral retrieval strategies. • Finding lost abandoned PCI equipment during cath-lab procedures is a unique event. • Managing lost guidewire fragments in aortic root using various percutaneous techniques • The coronary “Twisting Wire Technique” adapted for peripheral vessels

Authors

Institutions

Publication Details

Journal
Cardiovascular Revascularization Medicine Interesting Cases
Published
2024-11-08
DOI
https://doi.org/10.1016/j.crmic.2024.100048
Primary Topic
Cardiac Valve Diseases and Treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Abandoned guidewire recapture from aortic root using “Guidewire twirling technique”

Gaetano Chiricolo, Andréa Moretti, Vincenzo Bernardo, G Sangiorgi et al.
Cardiovascular Revascularization Medicine Interesting Cases
Cardiac Valve Diseases and Treatments
article

Abandoned guidewire recapture from aortic root using “Guidewire twirling technique”

Gaetano Chiricolo, Andréa Moretti, Vincenzo Bernardo, G Sangiorgi, Stefano Sasso, Marcello Marchetta
article en

Abstract

Percutaneous coronary intervention (PCI) is a common procedure for treating coronary artery disease, but it can be complicated by the loss and fracture of coronary guidewires within the vascular system, leading to severe complications such as vessel damage, occlusion, and embolization. This case report describes a unique and challenging scenario involving an 81-year-old male patient who, during an elective coronary angiography, was found to have a fractured and partially decoiled coronary guidewire extending from the aortic root to the left subclavian artery. The guidewire had likely been left in place during a previous procedure and was not documented in the patient's medical history. Given the potential for life-threatening complications, including occlusion of the left internal mammary artery graft, a percutaneous retrieval was attempted. Initial efforts using a snare system were unsuccessful. However, the guidewire was successfully retrieved using the “twirling guidewires” technique, which involved entangling the fractured wire with three 0.014-inch guidewires and carefully extracting it through a guide catheter. The patient avoided invasive surgery and was discharged without complications the day after. This case highlights the importance of recognizing and managing lost guidewire fragments using various percutaneous techniques, underscoring the need for interventional cardiologists to be adept in both coronary and peripheral retrieval strategies. • Finding lost abandoned PCI equipment during cath-lab procedures is a unique event. • Managing lost guidewire fragments in aortic root using various percutaneous techniques • The coronary “Twisting Wire Technique” adapted for peripheral vessels

Cardiovascular Revascularization Medicine Interesting CasesVol. 4
University of Rome Tor Vergata (IT), Policlinico Tor Vergata (IT)
Zero hunger
Openalex Percentile: Top 64%
Cardiac Valve Diseases and Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.