Advanced photodetector for hybrid PET-MRI systems

<ns3:p> Background Currently, a wide variety of silicon photomultipliers (SiPMs) are available, each designed for specific applications in fields such as science, medicine, and industry. Advances in production technology have led to the development of more sensitive and efficient photodiodes, which are critical for applications requiring precision, such as medical imaging. Methods A research group has been working on designing a highly sensitive photodiode to enhance the capabilities of next-generation PET-MRI scanners. This involves integrating micropixel avalanche photodiodes (MAPDs) to improve image resolution. The chosen design features deep-immersion MAPDs with a pixel size of 12 microns and a density of 1000 pixels per square millimeter, allowing for high-detail photon detection. The 4x4 mm <ns3:sup>2</ns3:sup> active area is optimized to balance sensitivity and size for high-resolution medical imaging. To produce these photodiodes, the group has outlined a production plan involving 20-inch silicon wafers grown using multiple techniques to enhance material properties. The Malaysian Institute of Microelectronic Systems (MIMOS), renowned for its expertise in optical microelectronics, was selected as the production center. With MIMOS' state-of-the-art facilities, the project aims to meet stringent medical diagnostics standards. Results The experimental results demonstrated that the MAPD-3NM photodiode achieved an amplification factor 1.8 times greater than the MAPD-3NK under optimal conditions. Its overvoltage range increased by 100%, reaching 4 V, enhancing photon detection and amplification. The MAPD-3NM also showed a significant reduction in dark current, about 3.5 times lower than the MAPD-3NK, improving performance in low-light environments. Additionally, the MAPD-3NM had a capacitance of 200 pF compared to 176 pF for the MAPD-3NK, contributing to its superior performance. These improvements make the MAPD-3NM more efficient and sensitive for scientific and medical applications. Conclusions This project represents a major advancement in photodetector technology for medical diagnostics, aiming to develop more accurate and efficient PET-MRI scanners that enhance patient outcomes with improved imaging capabilities. </ns3:p>

Authors

Publication Details

Journal
Open Research Europe
Published
2024-11-08
DOI
https://doi.org/10.12688/openreseurope.18695.1
Citations
2
Primary Topic
Medical Imaging Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.81

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Advanced photodetector for hybrid PET-MRI systems

N Sadigova, K Isayev, O Rasulov
2 citations
Open Research Europe
Medical Imaging Techniques and Applications
0.81
article

Advanced photodetector for hybrid PET-MRI systems

N Sadigova, K Isayev, O Rasulov
article en
2 citations

Abstract

<ns3:p> Background Currently, a wide variety of silicon photomultipliers (SiPMs) are available, each designed for specific applications in fields such as science, medicine, and industry. Advances in production technology have led to the development of more sensitive and efficient photodiodes, which are critical for applications requiring precision, such as medical imaging. Methods A research group has been working on designing a highly sensitive photodiode to enhance the capabilities of next-generation PET-MRI scanners. This involves integrating micropixel avalanche photodiodes (MAPDs) to improve image resolution. The chosen design features deep-immersion MAPDs with a pixel size of 12 microns and a density of 1000 pixels per square millimeter, allowing for high-detail photon detection. The 4x4 mm <ns3:sup>2</ns3:sup> active area is optimized to balance sensitivity and size for high-resolution medical imaging. To produce these photodiodes, the group has outlined a production plan involving 20-inch silicon wafers grown using multiple techniques to enhance material properties. The Malaysian Institute of Microelectronic Systems (MIMOS), renowned for its expertise in optical microelectronics, was selected as the production center. With MIMOS' state-of-the-art facilities, the project aims to meet stringent medical diagnostics standards. Results The experimental results demonstrated that the MAPD-3NM photodiode achieved an amplification factor 1.8 times greater than the MAPD-3NK under optimal conditions. Its overvoltage range increased by 100%, reaching 4 V, enhancing photon detection and amplification. The MAPD-3NM also showed a significant reduction in dark current, about 3.5 times lower than the MAPD-3NK, improving performance in low-light environments. Additionally, the MAPD-3NM had a capacitance of 200 pF compared to 176 pF for the MAPD-3NK, contributing to its superior performance. These improvements make the MAPD-3NM more efficient and sensitive for scientific and medical applications. Conclusions This project represents a major advancement in photodetector technology for medical diagnostics, aiming to develop more accurate and efficient PET-MRI scanners that enhance patient outcomes with improved imaging capabilities. </ns3:p>

Open Research EuropeVol. 4
HORIZON EUROPE Framework Programme
Industry, innovation and infrastructure
Openalex Percentile: Top 25%
Medical Imaging Techniques and Applications
0.81
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.