Logistic chaotic detection algorithm for bird damage tripping probability of 10kV distribution lines

Bird damage trip data may contain a lot of noise and outliers, which requires the detection algorithm to have strong data processing ability to accurately extract useful information from complex data. However, current detection algorithms may need to be improved in terms of data processing capabilities. Therefore, the Logistic chaotic detection algorithm of bird damage tripping probability of 10kV distribution line is designed. The fault current of 10kV distribution line is extracted, and the hierarchical model of bird hazard risk assessment based on geographical characteristics and tower structure characteristics is established. By using Logistic chaotic time series, the abnormal data component is extracted to realize the detection of bird damage tripping probability of 10kV distribution line. The experimental results show that the predicted results of the design method fit the real situation, the average relative error is reduced by 10%, and the average detection time is gradually reduced from 0.71 seconds in 10 iterations to 0.48 seconds in 50 iterations.

Authors

Institutions

Publication Details

Published
2024-11-08
DOI
https://doi.org/10.1117/12.3049757
Primary Topic
Remote Sensing and LiDAR Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Logistic chaotic detection algorithm for bird damage tripping probability of 10kV distribution lines

Ming Deng, Yun Zeng
Remote Sensing and LiDAR Applications
article

Logistic chaotic detection algorithm for bird damage tripping probability of 10kV distribution lines

Ming Deng, Yun Zeng
article en

Abstract

Bird damage trip data may contain a lot of noise and outliers, which requires the detection algorithm to have strong data processing ability to accurately extract useful information from complex data. However, current detection algorithms may need to be improved in terms of data processing capabilities. Therefore, the Logistic chaotic detection algorithm of bird damage tripping probability of 10kV distribution line is designed. The fault current of 10kV distribution line is extracted, and the hierarchical model of bird hazard risk assessment based on geographical characteristics and tower structure characteristics is established. By using Logistic chaotic time series, the abnormal data component is extracted to realize the detection of bird damage tripping probability of 10kV distribution line. The experimental results show that the predicted results of the design method fit the real situation, the average relative error is reduced by 10%, and the average detection time is gradually reduced from 0.71 seconds in 10 iterations to 0.48 seconds in 50 iterations.

China Southern Power Grid (China) (CN)
Openalex Percentile: Top 82%
Remote Sensing and LiDAR Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Logistic chaotic detection algorithm for bird damage tripping probability of 10kV distribution lines — Ming Deng, Yun Zeng · (2024) | TGRS Research Map | TGRS