SynNet3D: multi-view projection synthesis model for sparse-view CBCT reconstruction

This study proposes a multi-view projection synthesis model, named SynNet3D, to improve the quality of sparse-view low-dose cone-beam computed tomography (CBCT) images. Based on an attention 3D Res-UNet architecture, the proposed SynNet3D model generated projections of missing views in a single stage. The full-view projections were restored from the 1/4 sparse-view projections using the SynNet3D method, and subsequently reconstructed using the Feldkamp-Davis-Kress (FDK) technique. Quantitative metrics includes pixel-level evaluation metrics, such as root-mean-square error (RMSE) and peak signal-to-noise ratio (PSNR). It also includes two metrics for evaluating the perceptual quality of images from the perspective of the human visual system, such as structural similarity (SSIM) and feature similarity (FSIM). On the test set, the SynNet3D model achieved averaged RMSE, PSNR, SSIM and FSIM values of 0.0416, 43.4 dB, 0.975 and 0.993 in the image domain, respectively. The SynNet3D model outperformed the existing single-view projection synthesis model, SynCNN, across all metrics. In conclusion, the SynNet3D model can effectively enhance the performance of sparse-view CBCT images.

Authors

Institutions

Publication Details

Published
2024-11-08
DOI
https://doi.org/10.1117/12.3049753
Primary Topic
Medical Imaging Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

SynNet3D: multi-view projection synthesis model for sparse-view CBCT reconstruction

Jupeng Li, Lei Sui, Xuzhi Zhao, Yahui Peng et al.
Medical Imaging Techniques and Applications
article

SynNet3D: multi-view projection synthesis model for sparse-view CBCT reconstruction

Jupeng Li, Lei Sui, Xuzhi Zhao, Yahui Peng, Yi Du
article en

Abstract

This study proposes a multi-view projection synthesis model, named SynNet3D, to improve the quality of sparse-view low-dose cone-beam computed tomography (CBCT) images. Based on an attention 3D Res-UNet architecture, the proposed SynNet3D model generated projections of missing views in a single stage. The full-view projections were restored from the 1/4 sparse-view projections using the SynNet3D method, and subsequently reconstructed using the Feldkamp-Davis-Kress (FDK) technique. Quantitative metrics includes pixel-level evaluation metrics, such as root-mean-square error (RMSE) and peak signal-to-noise ratio (PSNR). It also includes two metrics for evaluating the perceptual quality of images from the perspective of the human visual system, such as structural similarity (SSIM) and feature similarity (FSIM). On the test set, the SynNet3D model achieved averaged RMSE, PSNR, SSIM and FSIM values of 0.0416, 43.4 dB, 0.975 and 0.993 in the image domain, respectively. The SynNet3D model outperformed the existing single-view projection synthesis model, SynCNN, across all metrics. In conclusion, the SynNet3D model can effectively enhance the performance of sparse-view CBCT images.

Peking University (CN), Beijing Jiaotong University (CN), Peking University Cancer Hospital (CN)
Sustainable cities and communities
Openalex Percentile: Top 67%
Medical Imaging Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.