Comparison of Computational Statistical Packages for the Analysis of Continuous Glucose Monitoring Data with a Reference Software, “Ambulatory Glucose Profile,” in Type 1 Diabetes

<b><i>Objective:</i></b> To compare the accuracy of commonly used continuous glucose monitoring (CGM) analysis programs with ambulatory glucose profile (AGP) and Dexcom Clarity (DC) in analyzing CGM metrics in patients with type 1 diabetes (T1D). <b><i>Research Methods:</i></b> CGM data up to 90 days from 152 adults using the same CGM and automated insulin delivery system with T1D were collected. Six of the 19 CGM analysis programs (CDGA, cgmanalysis, Glyculator, iglu, EasyGV, and GLU) were selected to compare with AGP and DC. Metrics were compared etween all tools with two one-sided <i>t</i>-tests equivalence testing. For the equivalence test, the acceptable range of deviation was set as ±2 mg/dL for mean glucose, ±2% for time in range (TIR), ±1% for time above range (TAR), time above range level 1 (TAR1), time above range level 2 (TAR2), and coefficient of variation (CV). <b><i>Results:</i></b> All packages were compared with each other for all CGM metrics, and most of them had statistically significant differences for at least some metrics. All tools were equivalent to AGP for mean glucose, TIR, TAR, TAR1, and TAR2 within ±2 mg/dL, ±2%, ±1%, ±1% and 1%, respectively. CDGA, Glyculator, cgmanalysis, and iglu were not equivalent to AGP for CV within ±1%. All tools were equivalent to DC for mean glucose, TIR, and TAR2 within ±2 mg/dL, ±2%, and ±1%, respectively. Glyculator was not equivalent for TAR1, TAR, and CV. CGDA, cgmanalysis, and iglu were not equivalent to DC for TAR1 and TAR. EasyGV and GLU were not equivalent for TAR within ±1%. <b><i>Conclusions:</i></b> CGM analysis programs reported CGM metrics statistically differently, but these differences may not be applicable in clinical practice. The equivalence test also confirmed that the differences are negligible for TIR and mean glucose, while they can be important for hyperglycemic ranges and CV. A standardization for CGM data handling and analysis is necessary for clinical studies reporting CGM-generated outcomes.

Authors

Institutions

Publication Details

Journal
Diabetes Technology & Therapeutics
Published
2024-11-08
DOI
https://doi.org/10.1089/dia.2024.0410
Citations
4
Primary Topic
Diabetes Management and Research
Type
article
Field-Weighted Citation Impact
1.43
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparison of Computational Statistical Packages for the Analysis of Continuous Glucose Monitoring Data with a Reference Software, “Ambulatory Glucose Profile,” in Type 1 Diabetes

Halis Kaan Aktürk, Kagan Ege Karakus, Janet K. Snell‐Bergeon
4 citations
Diabetes Technology & Therapeutics
Diabetes Management and Research
1.43
article

Comparison of Computational Statistical Packages for the Analysis of Continuous Glucose Monitoring Data with a Reference Software, “Ambulatory Glucose Profile,” in Type 1 Diabetes

Halis Kaan Aktürk, Kagan Ege Karakus, Janet K. Snell‐Bergeon
article en
4 citations

Abstract

<b><i>Objective:</i></b> To compare the accuracy of commonly used continuous glucose monitoring (CGM) analysis programs with ambulatory glucose profile (AGP) and Dexcom Clarity (DC) in analyzing CGM metrics in patients with type 1 diabetes (T1D). <b><i>Research Methods:</i></b> CGM data up to 90 days from 152 adults using the same CGM and automated insulin delivery system with T1D were collected. Six of the 19 CGM analysis programs (CDGA, cgmanalysis, Glyculator, iglu, EasyGV, and GLU) were selected to compare with AGP and DC. Metrics were compared etween all tools with two one-sided <i>t</i>-tests equivalence testing. For the equivalence test, the acceptable range of deviation was set as ±2 mg/dL for mean glucose, ±2% for time in range (TIR), ±1% for time above range (TAR), time above range level 1 (TAR1), time above range level 2 (TAR2), and coefficient of variation (CV). <b><i>Results:</i></b> All packages were compared with each other for all CGM metrics, and most of them had statistically significant differences for at least some metrics. All tools were equivalent to AGP for mean glucose, TIR, TAR, TAR1, and TAR2 within ±2 mg/dL, ±2%, ±1%, ±1% and 1%, respectively. CDGA, Glyculator, cgmanalysis, and iglu were not equivalent to AGP for CV within ±1%. All tools were equivalent to DC for mean glucose, TIR, and TAR2 within ±2 mg/dL, ±2%, and ±1%, respectively. Glyculator was not equivalent for TAR1, TAR, and CV. CGDA, cgmanalysis, and iglu were not equivalent to DC for TAR1 and TAR. EasyGV and GLU were not equivalent for TAR within ±1%. <b><i>Conclusions:</i></b> CGM analysis programs reported CGM metrics statistically differently, but these differences may not be applicable in clinical practice. The equivalence test also confirmed that the differences are negligible for TIR and mean glucose, while they can be important for hyperglycemic ranges and CV. A standardization for CGM data handling and analysis is necessary for clinical studies reporting CGM-generated outcomes.

Diabetes Technology & TherapeuticsVol. 27(3)
University of Colorado Anschutz Medical Campus (US)
Openalex Percentile: Top 15%
Diabetes Management and Research
1.43
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.