Effects of boundary conditions on the transmitral pressure gradient for numerical simulation of flow in a left heart model

The transmitral pressure gradient is a crucial clinical indicator for diagnosing mitral regurgitation and stenosis. Numerical simulation of specific patients can obtain the complete pressure distribution in the left heart system, which is an important approach to evaluate cardiac function. However, the results are sensitive to the boundary conditions used in the numerical simulations. In the present work, we constructed a left heart model and assessed the effects of four typical boundary conditions on the transmitral pressure gradient, which is computed based on the Bernoulli equation and the line probe, respectively. The results show that the transmitral pressure gradient obtained by the line probe is sensitive to the boundary conditions. The sensitivity is closely related to the pressure in the atrium but has negligible effect on the pressure in the ventricle. This study sheds light on evaluating the pressure gradient of patient-specific treatments based on the numerical simulation of a left heart model.

Authors

Institutions

Publication Details

Journal
Physics of Fluids
Published
2024-11-01
DOI
https://doi.org/10.1063/5.0228808
Citations
1
Primary Topic
Cardiovascular Function and Risk Factors
Type
article
Field-Weighted Citation Impact
0.40

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effects of boundary conditions on the transmitral pressure gradient for numerical simulation of flow in a left heart model

Hongping Wang, Shizhao Wang, Pengxu Kong, Fan Wu et al.
1 citations
Physics of Fluids
Cardiovascular Function and Risk Factors
0.40
article

Effects of boundary conditions on the transmitral pressure gradient for numerical simulation of flow in a left heart model

Hongping Wang, Shizhao Wang, Pengxu Kong, Fan Wu, Peijian Wei, Shuyi Feng, Xinyi He, Xiangbin Pan
article en
1 citations

Abstract

The transmitral pressure gradient is a crucial clinical indicator for diagnosing mitral regurgitation and stenosis. Numerical simulation of specific patients can obtain the complete pressure distribution in the left heart system, which is an important approach to evaluate cardiac function. However, the results are sensitive to the boundary conditions used in the numerical simulations. In the present work, we constructed a left heart model and assessed the effects of four typical boundary conditions on the transmitral pressure gradient, which is computed based on the Bernoulli equation and the line probe, respectively. The results show that the transmitral pressure gradient obtained by the line probe is sensitive to the boundary conditions. The sensitivity is closely related to the pressure in the atrium but has negligible effect on the pressure in the ventricle. This study sheds light on evaluating the pressure gradient of patient-specific treatments based on the numerical simulation of a left heart model.

Physics of FluidsVol. 36(11)
Chinese Academy of Sciences (CN), Chinese Academy of Medical Sciences & Peking Union Medical College (CN), National Health and Family Planning Commission (CN), Institute of Mechanics (CN), University of Chinese Academy of Sciences (CN)
National Natural Science Foundation of China, Fundamental Research Funds for the Central Universities
Openalex Percentile: Top 31%
Cardiovascular Function and Risk Factors
0.40
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.