Grid impedance measurement for inverters with current controllers and virtual impedances

Modern inverter controllers such as the virtual synchronous machine (VSM) and other types of grid forming (GFM) inverters integrate an output current controller (OCC) and virtual admittances. The control structure is organized hierarchically; a higher level (slow) controller that generates reference voltages based on the control paradigm of the GFM, and the lower level (fast) OCC are combined to control the inverter. The voltage differences between these reference voltages and the grid voltages measured on the filter capacitors of the inverter are applied to the virtual admittance to obtain the reference currents that are employed by the OCC. The stability of such a combined control structure is known to depend strongly on the short circuit ratio (SCR) of the connecting line between the inverter and the grid. In particular, with lower SCRs, the region of stable operating points decreases. In order to be able to determine the strength of the connecting line of such an inverter and to adapt the tuning of the machine, this paper investigates a method for probing the grid impedance by injecting a small amplitude disturbance into the control loop of the GFM. Based on the measurement of the reaction of the grid voltages, it is possible to obtain an estimate of the grid resistance and inductance.

Authors

Institutions

Publication Details

Published
2024-09-16
DOI
https://doi.org/10.1109/isap63260.2024.10744252
Citations
3
Primary Topic
Multilevel Inverters and Converters
Type
article
Field-Weighted Citation Impact
0.63

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Grid impedance measurement for inverters with current controllers and virtual impedances

George H. Weiss, Florian Reißner
3 citations
Multilevel Inverters and Converters
0.63
article

Grid impedance measurement for inverters with current controllers and virtual impedances

George H. Weiss, Florian Reißner
article en
3 citations

Abstract

Modern inverter controllers such as the virtual synchronous machine (VSM) and other types of grid forming (GFM) inverters integrate an output current controller (OCC) and virtual admittances. The control structure is organized hierarchically; a higher level (slow) controller that generates reference voltages based on the control paradigm of the GFM, and the lower level (fast) OCC are combined to control the inverter. The voltage differences between these reference voltages and the grid voltages measured on the filter capacitors of the inverter are applied to the virtual admittance to obtain the reference currents that are employed by the OCC. The stability of such a combined control structure is known to depend strongly on the short circuit ratio (SCR) of the connecting line between the inverter and the grid. In particular, with lower SCRs, the region of stable operating points decreases. In order to be able to determine the strength of the connecting line of such an inverter and to adapt the tuning of the machine, this paper investigates a method for probing the grid impedance by injecting a small amplitude disturbance into the control loop of the GFM. Based on the measurement of the reaction of the grid voltages, it is possible to obtain an estimate of the grid resistance and inductance.

Tel Aviv University (IL)
Israel Science Foundation
Affordable and clean energy
Openalex Percentile: Top 31%
Multilevel Inverters and Converters
0.63
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.