Physics-Informed Score-Based Diffusion Model for Limited-Angle Reconstruction of Cardiac Computed Tomography

Cardiac computed tomography (CT) has emerged as a major imaging modality for the diagnosis and monitoring of cardiovascular diseases. High temporal resolution is essential to ensure diagnostic accuracy. Limited-angle data acquisition can reduce scan time and improve temporal resolution, but typically leads to severe image degradation and motivates for improved reconstruction techniques. In this paper, we propose a novel physics-informed score-based diffusion model (PSDM) for limited-angle reconstruction of cardiac CT. At the sampling time, we combine a data prior from a diffusion model and a model prior obtained via an iterative algorithm and Fourier fusion to further enhance the image quality. Specifically, our approach integrates the primal-dual hybrid gradient (PDHG) algorithm with score-based diffusion models, thereby enabling us to reconstruct high-quality cardiac CT images from limited-angle data. The numerical simulations and real data experiments confirm the effectiveness of our proposed approach.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Medical Imaging
Published
2024-11-08
DOI
https://doi.org/10.1109/tmi.2024.3494271
Citations
9
Primary Topic
Advanced X-ray and CT Imaging
Type
article
Field-Weighted Citation Impact
1.66

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Physics-Informed Score-Based Diffusion Model for Limited-Angle Reconstruction of Cardiac Computed Tomography

Yongshun Xu, Hengyong Yu, Jonathan S. Maltz, Bahareh Morovati et al.
9 citations
IEEE Transactions on Medical Imaging
Advanced X-ray and CT Imaging
1.66
article

Physics-Informed Score-Based Diffusion Model for Limited-Angle Reconstruction of Cardiac Computed Tomography

Yongshun Xu, Hengyong Yu, Jonathan S. Maltz, Bahareh Morovati, Ge Wang, L. P. Zhou, Dayang Wang, Shuo Han
article en
9 citations

Abstract

Cardiac computed tomography (CT) has emerged as a major imaging modality for the diagnosis and monitoring of cardiovascular diseases. High temporal resolution is essential to ensure diagnostic accuracy. Limited-angle data acquisition can reduce scan time and improve temporal resolution, but typically leads to severe image degradation and motivates for improved reconstruction techniques. In this paper, we propose a novel physics-informed score-based diffusion model (PSDM) for limited-angle reconstruction of cardiac CT. At the sampling time, we combine a data prior from a diffusion model and a model prior obtained via an iterative algorithm and Fourier fusion to further enhance the image quality. Specifically, our approach integrates the primal-dual hybrid gradient (PDHG) algorithm with score-based diffusion models, thereby enabling us to reconstruct high-quality cardiac CT images from limited-angle data. The numerical simulations and real data experiments confirm the effectiveness of our proposed approach.

IEEE Transactions on Medical ImagingVol. 44(9)
University of Massachusetts Lowell (US), Rensselaer Polytechnic Institute (US)
National Institutes of Health, National Institute of Biomedical Imaging and Bioengineering
Openalex Percentile: Top 17%
Advanced X-ray and CT Imaging
1.66
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.