A Novel Fault-Tolerant Operation Approach for Cascaded H-Bridge Converter-Based Battery Energy Storage Systems to Avoid Overcharge

Conventional fundamental frequency zero-sequence voltage (FFZSV) injection-based fault-tolerant operation methods cause power reversion under submodule (SM) failure conditions with low-power factor, which leads to overcharge risk in the cascaded H-bridge converter-based battery energy storage system (CHB-BESS). To solve this issue, a novel fault-tolerant operation approach has been proposed for the CHB-BESS. First, the power reversion mechanism and overcharge risk are analyzed with the conventional FFZSV injection-based methods. On this basis, the operation conditions of the CHB-BESS are divided into three stages according to the safe FFZSV injection region, the FFZSV is modified, and the negative sequence current is injected when necessary. As a result, the power flow of battery packs among the three phases can maintain the same direction, and the power reversion and overcharge risk can be avoided. Experimental results under various conditions verify that the proposed fault-tolerant operation approach of the CHB-BESS can achieve uninterrupted operation and avoid overcharge risk.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Industrial Electronics
Published
2024-11-08
DOI
https://doi.org/10.1109/tie.2024.3485716
Citations
12
Primary Topic
Microgrid Control and Optimization
Type
article
Field-Weighted Citation Impact
3.94
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Novel Fault-Tolerant Operation Approach for Cascaded H-Bridge Converter-Based Battery Energy Storage Systems to Avoid Overcharge

Yu Jin, Remus Teodorescu, Frede Blaabjerg, Hongjie Jia et al.
12 citations
IEEE Transactions on Industrial Electronics
Microgrid Control and Optimization
3.94
article

A Novel Fault-Tolerant Operation Approach for Cascaded H-Bridge Converter-Based Battery Energy Storage Systems to Avoid Overcharge

Yu Jin, Remus Teodorescu, Frede Blaabjerg, Hongjie Jia, Yunfei Mu, Qian Xiao, Haolin Yu, Wenhua Li, Huiqiao Liu
article en
12 citations

Abstract

Conventional fundamental frequency zero-sequence voltage (FFZSV) injection-based fault-tolerant operation methods cause power reversion under submodule (SM) failure conditions with low-power factor, which leads to overcharge risk in the cascaded H-bridge converter-based battery energy storage system (CHB-BESS). To solve this issue, a novel fault-tolerant operation approach has been proposed for the CHB-BESS. First, the power reversion mechanism and overcharge risk are analyzed with the conventional FFZSV injection-based methods. On this basis, the operation conditions of the CHB-BESS are divided into three stages according to the safe FFZSV injection region, the FFZSV is modified, and the negative sequence current is injected when necessary. As a result, the power flow of battery packs among the three phases can maintain the same direction, and the power reversion and overcharge risk can be avoided. Experimental results under various conditions verify that the proposed fault-tolerant operation approach of the CHB-BESS can achieve uninterrupted operation and avoid overcharge risk.

IEEE Transactions on Industrial ElectronicsVol. 72(6)
Tianjin University (CN), Hebei University of Technology (CN), Aalborg University (DK)
Affordable and clean energy
Openalex Percentile: Top 6%
Microgrid Control and Optimization
3.94
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.