LSMD: Long-Short Memory-Based Detection Network for Carotid Artery Detection in B-Mode Ultrasound Video Streams

Carotid atherosclerotic plaques are a major complication associated with type II diabetes, and carotid ultrasound is commonly used for diagnosing carotid vascular disease. In primary hospitals, less experienced ultrasound physicians often struggle to consistently capture standard carotid images and identify plaques. To address this issue, we propose a novel approach, the long-short memory-based detection (LSMD) network, for carotid artery detection in ultrasound video streams, facilitating the identification and localization of critical anatomical structures and plaques. This approach models short- and long-distance spatiotemporal features through short-term temporal aggregation (STA) and long-term temporal aggregation (LTA) modules, effectively expanding the temporal receptive field with minimal delay and enhancing the detection efficiency of carotid anatomy and plaques. Specifically, we introduce memory buffers with a dynamic updating strategy to ensure extensive temporal receptive field coverage while minimizing memory and computation costs. The proposed model was trained on 80 carotid ultrasound videos and evaluated on 50, with all videos annotated by physicians for carotid anatomies and plaques. The trained LSMD was evaluated for performance on the validation and test sets using the single-frame image-based single shot multibox detector (SSD) algorithm as a baseline. The results show that the precision, recall, average precision (AP) at ( ), and mean AP (mAP) are 6.83%, 12.29%, 11.23%, and 13.21% higher than the baseline ( ), respectively, while the model's inference latency reaches 6.97 ms on a desktop-level GPU (NVIDIA RTX 3090Ti) and 29.69 ms on an edge computing device (Jetson Orin Nano). These findings demonstrate that LSMD can accurately localize carotid anatomy and plaques with real-time inference, indicating its potential for enhancing diagnostic accuracy in clinical practice.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control
Published
2024-11-01
DOI
https://doi.org/10.1109/tuffc.2024.3494019
Citations
3
Primary Topic
Cardiovascular Health and Disease Prevention
Type
article
Field-Weighted Citation Impact
1.21
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

LSMD: Long-Short Memory-Based Detection Network for Carotid Artery Detection in B-Mode Ultrasound Video Streams

Yidi Chen, Chunjie Shan, Shouhua Luo, Zhibin Jin et al.
3 citations
IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control
Cardiovascular Health and Disease Prevention
1.21
article

LSMD: Long-Short Memory-Based Detection Network for Carotid Artery Detection in B-Mode Ultrasound Video Streams

Yidi Chen, Chunjie Shan, Shouhua Luo, Zhibin Jin, Yidan Zhang, Heng-Da Cheng, Chunrui Liu, Jing Yao
article en
3 citations

Abstract

Carotid atherosclerotic plaques are a major complication associated with type II diabetes, and carotid ultrasound is commonly used for diagnosing carotid vascular disease. In primary hospitals, less experienced ultrasound physicians often struggle to consistently capture standard carotid images and identify plaques. To address this issue, we propose a novel approach, the long-short memory-based detection (LSMD) network, for carotid artery detection in ultrasound video streams, facilitating the identification and localization of critical anatomical structures and plaques. This approach models short- and long-distance spatiotemporal features through short-term temporal aggregation (STA) and long-term temporal aggregation (LTA) modules, effectively expanding the temporal receptive field with minimal delay and enhancing the detection efficiency of carotid anatomy and plaques. Specifically, we introduce memory buffers with a dynamic updating strategy to ensure extensive temporal receptive field coverage while minimizing memory and computation costs. The proposed model was trained on 80 carotid ultrasound videos and evaluated on 50, with all videos annotated by physicians for carotid anatomies and plaques. The trained LSMD was evaluated for performance on the validation and test sets using the single-frame image-based single shot multibox detector (SSD) algorithm as a baseline. The results show that the precision, recall, average precision (AP) at ( ), and mean AP (mAP) are 6.83%, 12.29%, 11.23%, and 13.21% higher than the baseline ( ), respectively, while the model's inference latency reaches 6.97 ms on a desktop-level GPU (NVIDIA RTX 3090Ti) and 29.69 ms on an edge computing device (Jetson Orin Nano). These findings demonstrate that LSMD can accurately localize carotid anatomy and plaques with real-time inference, indicating its potential for enhancing diagnostic accuracy in clinical practice.

IEEE Transactions on Ultrasonics Ferroelectrics and Frequency ControlVol. 71(11)
Nanjing Drum Tower Hospital (CN), Southeast University (CN)
Openalex Percentile: Top 18%
Cardiovascular Health and Disease Prevention
1.21
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.