Enhancing prediction stability and performance in LIBS analysis using custom CNN architectures

LIBS-based analysis has experienced an ever-increasing interest in recent years as a well-suited technique for chemical analysis tasks relying on elemental fingerprinting. This method stands out for its ability to offer rapid, simultaneous multi-element analysis with the advantage of portability. In the context of this research, our aim is to bridge the gap between the analysis of simulated and real data to better account for variations in plasma temperature and electron density, which are typically not considered in LIBS analysis. To achieve this, we employ two distinct methodologies, PLS and CNNs, to construct predictive models for predicting the concentration of the 24 elements within each LIBS spectrum. The initial phase of our investigation concentrates on the training and testing of these models using simulated LIBS data, with results evaluated through RMSEP values. The IQR and median RMSEP values for all the elements demonstrate that CNNs consistently achieved values below 0.01, while PLS results ranged from 0.01 to 0.05, highlighting the superior stability and predictive accuracy of CNNs model. In the next phase, we applied the pre-trained models to analyze the real LIBS spectra, consistently identifying Aluminum (Al), Iron (Fe), and Silicon (Si) as having the highest predicted concentrations. The overall predicted values were approximately 0.5 for Al, 0.6 for Si, and 0.04 for Fe. In the third phase, deliberate adjustments are made to the training parameters and architecture of the proposed CNNs model to force the network to emphasize specific elements, prioritizing them over other components present in each real LIBS spectrum. The generation of the three modified versions of the initially proposed CNNs allows us to explore the impact of regularization, sample weighting, and a customized loss function on prediction outcomes. Some elements emerge during the prediction phase, with Calcium (Ca), Magnesium (Mg), Zinc (Zn), Titanium (Ti), and Gallium (Ga) exhibiting more pronounced patterns.

Authors

Institutions

Publication Details

Journal
Talanta
Published
2024-11-08
DOI
https://doi.org/10.1016/j.talanta.2024.127192
Citations
9
Primary Topic
Laser-induced spectroscopy and plasma
Type
article
Field-Weighted Citation Impact
2.42

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Enhancing prediction stability and performance in LIBS analysis using custom CNN architectures

Ludovic Duponchel, Thomas Wilhelm Bocklitz, Vincent Motto‐Ros, Pegah Dehbozorgi
9 citations
Talanta
Laser-induced spectroscopy and plasma
2.42
article

Enhancing prediction stability and performance in LIBS analysis using custom CNN architectures

Ludovic Duponchel, Thomas Wilhelm Bocklitz, Vincent Motto‐Ros, Pegah Dehbozorgi
article en
9 citations

Abstract

LIBS-based analysis has experienced an ever-increasing interest in recent years as a well-suited technique for chemical analysis tasks relying on elemental fingerprinting. This method stands out for its ability to offer rapid, simultaneous multi-element analysis with the advantage of portability. In the context of this research, our aim is to bridge the gap between the analysis of simulated and real data to better account for variations in plasma temperature and electron density, which are typically not considered in LIBS analysis. To achieve this, we employ two distinct methodologies, PLS and CNNs, to construct predictive models for predicting the concentration of the 24 elements within each LIBS spectrum. The initial phase of our investigation concentrates on the training and testing of these models using simulated LIBS data, with results evaluated through RMSEP values. The IQR and median RMSEP values for all the elements demonstrate that CNNs consistently achieved values below 0.01, while PLS results ranged from 0.01 to 0.05, highlighting the superior stability and predictive accuracy of CNNs model. In the next phase, we applied the pre-trained models to analyze the real LIBS spectra, consistently identifying Aluminum (Al), Iron (Fe), and Silicon (Si) as having the highest predicted concentrations. The overall predicted values were approximately 0.5 for Al, 0.6 for Si, and 0.04 for Fe. In the third phase, deliberate adjustments are made to the training parameters and architecture of the proposed CNNs model to force the network to emphasize specific elements, prioritizing them over other components present in each real LIBS spectrum. The generation of the three modified versions of the initially proposed CNNs allows us to explore the impact of regularization, sample weighting, and a customized loss function on prediction outcomes. Some elements emerge during the prediction phase, with Calcium (Ca), Magnesium (Mg), Zinc (Zn), Titanium (Ti), and Gallium (Ga) exhibiting more pronounced patterns.

TalantaVol. 284
Université Claude Bernard Lyon 1 (FR), Centre National de la Recherche Scientifique (FR), Université de Lille (FR), Leibniz Institute of Photonic Technology (DE), Institut Lumière Matière (FR)
Bundesministerium für Bildung und Forschung, Bundesministerium für Bildung, Wissenschaft, Forschung und Technologie
Openalex Percentile: Top 11%
Laser-induced spectroscopy and plasma
2.42
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.