Application of an 800 Gold Microelectrode Array for Rapid Voltammetric Detection of Nitrite Pollution in Environmental Waters

A simple voltammetric procedure for direct determination of nitrites in natural water samples is described. Measurements are carried out in an inert medium of 0.1 M KCl. The procedure is based on the oxidation of N(III) to N(V) as a result of a change in electrode potential from +0.40 V to +0.96 V. The use of a combined electrode consisting of approximately 800 gold microelectrodes enables undisturbed determinations to be performed in the presence of high concentrations of organic compounds at a level of 20 mg l −1 . The calibration plot for NO 2 − was linear in the range from 2 × 10 −6 to 8 × 10 −4 M with a detection limit of 6 × 10 −7 M. The proposed procedure was successfully applied to nitrate determination in three natural water samples with passable results.

Authors

Publication Details

Journal
Journal of The Electrochemical Society
Published
2024-11-01
DOI
https://doi.org/10.1149/1945-7111/ad9062
Citations
2
Primary Topic
Water Quality Monitoring and Analysis
Type
article
Field-Weighted Citation Impact
0.59
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Application of an 800 Gold Microelectrode Array for Rapid Voltammetric Detection of Nitrite Pollution in Environmental Waters

Marzena Adamczyk, Małgorzata Grabarczyk
2 citations
Journal of The Electrochemical Society
Water Quality Monitoring and Analysis
0.59
article

Application of an 800 Gold Microelectrode Array for Rapid Voltammetric Detection of Nitrite Pollution in Environmental Waters

Marzena Adamczyk, Małgorzata Grabarczyk
article en
2 citations

Abstract

A simple voltammetric procedure for direct determination of nitrites in natural water samples is described. Measurements are carried out in an inert medium of 0.1 M KCl. The procedure is based on the oxidation of N(III) to N(V) as a result of a change in electrode potential from +0.40 V to +0.96 V. The use of a combined electrode consisting of approximately 800 gold microelectrodes enables undisturbed determinations to be performed in the presence of high concentrations of organic compounds at a level of 20 mg l −1 . The calibration plot for NO 2 − was linear in the range from 2 × 10 −6 to 8 × 10 −4 M with a detection limit of 6 × 10 −7 M. The proposed procedure was successfully applied to nitrate determination in three natural water samples with passable results.

Journal of The Electrochemical SocietyVol. 171(11)
Openalex Percentile: Top 29%
Water Quality Monitoring and Analysis
0.59
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Application of an 800 Gold Microelectrode Array for Rapid Voltammetric Detection of Nitrite Pollution in Environmental Waters — Marzena Adamczyk, Małgorzata Grabarczyk · Journal of The Electrochemical Society (2024) | TGRS Research Map | TGRS