A simplified approach to counting statistics with an imperfect pileup rejector

A simplified theoretical model is developed to predict counting statistics for a stationary Poisson process passing through a spectrometer with pulse-pileup rejection. The model is applicable to digital counters used for spectrometry as well as set-ups utilising analogue electronics for pulse shaping and pileup rejection. In comparison with an existing model for a perfect pileup rejector, the new model addresses the common imperfection of having a finite time resolution of the fast channel, allowing quasi-coincident signals to pass through the pile-up rejector. From the Laplace transform of a simplified interval-density distribution, approximate expressions are derived for the throughput factor and the variance of the number of counted events. The results are compared with computer simulations of a cascade of extending dead time and subsequent pileup rejection. In addition, a rigorous throughput factor is derived from probabilistic reasoning, as well as an effective throughput factor for singular and coincident events.

Authors

Institutions

Publication Details

Journal
Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment
Published
2024-11-08
DOI
https://doi.org/10.1016/j.nima.2024.170067
Citations
3
Primary Topic
Radioactive Decay and Measurement Techniques
Type
article
Field-Weighted Citation Impact
1.82

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A simplified approach to counting statistics with an imperfect pileup rejector

S. Pommé, K. Pelczar
3 citations
Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment
Radioactive Decay and Measurement Techniques
1.82
article

A simplified approach to counting statistics with an imperfect pileup rejector

S. Pommé, K. Pelczar
article en
3 citations

Abstract

A simplified theoretical model is developed to predict counting statistics for a stationary Poisson process passing through a spectrometer with pulse-pileup rejection. The model is applicable to digital counters used for spectrometry as well as set-ups utilising analogue electronics for pulse shaping and pileup rejection. In comparison with an existing model for a perfect pileup rejector, the new model addresses the common imperfection of having a finite time resolution of the fast channel, allowing quasi-coincident signals to pass through the pile-up rejector. From the Laplace transform of a simplified interval-density distribution, approximate expressions are derived for the throughput factor and the variance of the number of counted events. The results are compared with computer simulations of a cascade of extending dead time and subsequent pileup rejection. In addition, a rigorous throughput factor is derived from probabilistic reasoning, as well as an effective throughput factor for singular and coincident events.

Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated EquipmentVol. 1070
European Commission (BE)
Joint Research Centre
Openalex Percentile: Top 15%
Radioactive Decay and Measurement Techniques
1.82
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

A simplified approach to counting statistics with an imperfect pileup rejector — S. Pommé, K. Pelczar · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment (2024) | TGRS Research Map | TGRS