Characteristics of powder charging behavior via forced triboelectric charging on an inclined chute

This study presents a novel method for selective charging of powders by dry triboelectric forced charging utilized as the first stage of material sorting in an electric field. In forced triboelectric charging, a high voltage is applied to the copper chute in which particles are charged during their transportation. In this research, the effect of the operating parameters of the chute, including mass flow rate, angle of inclination, and length, on the specific particle charge of limestone powders was investigated. In addition, the behavior of the charged particles in an electrostatic sorter was analyzed by evaluating their charge distribution after sorting. The results reveal that as the length of the chute increases, the specific charge asymptotically approaches a saturation value, which is determined by the high voltage applied. Furthermore, for a given chute length, the high voltage influences the amount and the sign of the specific particle charge, including a high voltage value at which the particles are neutral on average, i.e. the so-called point of zero net charge (PZNC). This PZNC is of particular interest for sorting out a target component from a powder mixture. However, if the mass flow rate is increased above a certain value, the specific charge decreases as the number of particle wall contacts is reduced due to stratification. Bipolar charge distributions were observed for all investigated high voltages, with the distribution width increasing with particle size to the power of 2.1. The modal value of the charge distribution shifts according to the difference in voltage applied to the PZNC. • Forced triboelectric charging to charge particles and control the charging behavior. • Operational parameter effects of the triboelectric charger on charging efficiency. • Charge distribution analysis in a electro static sorter. • Reveal how particle size and surface properties influence charging.

Authors

Institutions

Publication Details

Journal
Powder Technology
Published
2024-11-08
DOI
https://doi.org/10.1016/j.powtec.2024.120400
Citations
4
Primary Topic
Advanced Sensor and Energy Harvesting Materials
Type
article
Field-Weighted Citation Impact
0.74

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Characteristics of powder charging behavior via forced triboelectric charging on an inclined chute

Alfred P. Weber, Annett Wollmann, Mehran Javadi, Mohamed Abohelwa
4 citations
Powder Technology
Advanced Sensor and Energy Harvesting Materials
0.74
article

Characteristics of powder charging behavior via forced triboelectric charging on an inclined chute

Alfred P. Weber, Annett Wollmann, Mehran Javadi, Mohamed Abohelwa
article en
4 citations

Abstract

This study presents a novel method for selective charging of powders by dry triboelectric forced charging utilized as the first stage of material sorting in an electric field. In forced triboelectric charging, a high voltage is applied to the copper chute in which particles are charged during their transportation. In this research, the effect of the operating parameters of the chute, including mass flow rate, angle of inclination, and length, on the specific particle charge of limestone powders was investigated. In addition, the behavior of the charged particles in an electrostatic sorter was analyzed by evaluating their charge distribution after sorting. The results reveal that as the length of the chute increases, the specific charge asymptotically approaches a saturation value, which is determined by the high voltage applied. Furthermore, for a given chute length, the high voltage influences the amount and the sign of the specific particle charge, including a high voltage value at which the particles are neutral on average, i.e. the so-called point of zero net charge (PZNC). This PZNC is of particular interest for sorting out a target component from a powder mixture. However, if the mass flow rate is increased above a certain value, the specific charge decreases as the number of particle wall contacts is reduced due to stratification. Bipolar charge distributions were observed for all investigated high voltages, with the distribution width increasing with particle size to the power of 2.1. The modal value of the charge distribution shifts according to the difference in voltage applied to the PZNC. • Forced triboelectric charging to charge particles and control the charging behavior. • Operational parameter effects of the triboelectric charger on charging efficiency. • Charge distribution analysis in a electro static sorter. • Reveal how particle size and surface properties influence charging.

Powder TechnologyVol. 449
Clausthal University of Technology (DE)
Deutsche Forschungsgemeinschaft
Openalex Percentile: Top 31%
Advanced Sensor and Energy Harvesting Materials
0.74
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.