Ultrafast 3D synthetic aperture imaging with Hadamard-encoded aperiodic interval codes and aperiodic sparse arrays with separate transmitters and receivers

3D synthetic aperture (SA) imaging of volumes can be obtained using sparse 2D ultrasound arrays. However, even with just 256 elements, the volumetric imaging rate can be relatively slow due to having to transmit on each element in succession. Hadamard Aperiodic Interval (HAPI) codes can be used to image the full SA dataset in one extended transmit to speed up the synthetic aperture imaging, but their long nature produces large deadzones if the same elements are used as both transmitters and receivers. In this simulation study, we use a 2D Costas sparse array with separate transmitters and receivers to remedy the deadzone problem, and use it with the HAPI-coded imaging scheme to obtain fully transmit-receive focused, wide field-of-view 3D volumes with high-resolution and high SNR at ultrafast volumetric imaging rates of more than 500 volumes per second, almost nine times faster than non-coded SA imaging with the same imaging parameters. We show similar PSF performance compared to non-coded SA, and a 26 dB improvement in SNR with order-256 HAPI codes. We also present cyst simulations showing similar contrast for the HAPI-coded SA method compared to non-coded SA in the context of no noise, and improved contrast in the context of noise.

Authors

Institutions

Publication Details

Journal
Ultrasonics
Published
2024-11-08
DOI
https://doi.org/10.1016/j.ultras.2024.107497
Citations
2
Primary Topic
Ultrasound Imaging and Elastography
Type
article
Field-Weighted Citation Impact
0.81
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Ultrafast 3D synthetic aperture imaging with Hadamard-encoded aperiodic interval codes and aperiodic sparse arrays with separate transmitters and receivers

Tarek Kaddoura, Roger J. Zemp, Mohammad Masoumi
2 citations
Ultrasonics
Ultrasound Imaging and Elastography
0.81
article

Ultrafast 3D synthetic aperture imaging with Hadamard-encoded aperiodic interval codes and aperiodic sparse arrays with separate transmitters and receivers

Tarek Kaddoura, Roger J. Zemp, Mohammad Masoumi
article en
2 citations

Abstract

3D synthetic aperture (SA) imaging of volumes can be obtained using sparse 2D ultrasound arrays. However, even with just 256 elements, the volumetric imaging rate can be relatively slow due to having to transmit on each element in succession. Hadamard Aperiodic Interval (HAPI) codes can be used to image the full SA dataset in one extended transmit to speed up the synthetic aperture imaging, but their long nature produces large deadzones if the same elements are used as both transmitters and receivers. In this simulation study, we use a 2D Costas sparse array with separate transmitters and receivers to remedy the deadzone problem, and use it with the HAPI-coded imaging scheme to obtain fully transmit-receive focused, wide field-of-view 3D volumes with high-resolution and high SNR at ultrafast volumetric imaging rates of more than 500 volumes per second, almost nine times faster than non-coded SA imaging with the same imaging parameters. We show similar PSF performance compared to non-coded SA, and a 26 dB improvement in SNR with order-256 HAPI codes. We also present cyst simulations showing similar contrast for the HAPI-coded SA method compared to non-coded SA in the context of no noise, and improved contrast in the context of noise.

UltrasonicsVol. 147
University of Alberta (CA)
Openalex Percentile: Top 25%
Ultrasound Imaging and Elastography
0.81
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.