Assessing the Effectiveness of Risk-Oriented Handwashing in Cardiac Surgery

Relevance. Healthcare-associated infections are a serious complication worldwide, with improper hand cleaning thought to be the main cause. Compliance with handwashing requirements is achieved in only 38% of cases. A risk management technology is the implementation of a standard operating procedure in practice, and an effective tool for analyzing non-compliance with its standards is an audit system that allows you to respond in a timely manner to existing deviations. The introduction of a system of audits of the epidemiological safety of medical technologies seems to be one of the directions of the risk-based approach to the prevention of infectious complications. Aim. To evaluate the effectiveness of hand sanitizing technology audits as a tool to reduce the risk of infections. Materials and methods . Over a three-year period, an audit of handwashing was carried out in four departments of the cardiac surgery center, during which 9924 checklists were analyzed. The audit itself took place according to the methodological recommendations we had previously developed. The audit results were processed in Microsoft Excel to form a database. Risk grading was carried out for each checklist using the risk matrix and the Percentile function in increments of 0.25 Results. During the audit, 5 items related to hand treatment technology were assessed: equipment of the workplace for hand treatment, hand treatment technology, the presence of antiseptic in areas of mandatory hand treatment, epidemiological safety during manipulation and patient care, organization of the hand treatment system. Initially, the risk in all positions was assessed as high, the implementation of corrective measures reduced the risk of infections associated with the provision of medical care to low values, and the incidence of infections in the cardiac surgery hospital decreased from 3.42 to 1.25 per 1000 patient days. Conclusion. The introduction of an audit system for hand sanitizing technology is an effective measure to reduce the risk of infection.

Authors

Institutions

Publication Details

Journal
Epidemiology and Vaccinal Prevention
Published
2024-11-06
DOI
https://doi.org/10.31631/2073-3046-2024-23-5-56-62
Citations
2
Primary Topic
Patient Safety and Medication Errors
Type
article
Field-Weighted Citation Impact
1.49
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Assessing the Effectiveness of Risk-Oriented Handwashing in Cardiac Surgery

Н. В. Кондрикова, О. Л. Барбараш, Е. Б. Брусина, Evgeny Evgenievich Sadovnikov
2 citations
Epidemiology and Vaccinal Prevention
Patient Safety and Medication Errors
1.49
article

Assessing the Effectiveness of Risk-Oriented Handwashing in Cardiac Surgery

Н. В. Кондрикова, О. Л. Барбараш, Е. Б. Брусина, Evgeny Evgenievich Sadovnikov
article en
2 citations

Abstract

Relevance. Healthcare-associated infections are a serious complication worldwide, with improper hand cleaning thought to be the main cause. Compliance with handwashing requirements is achieved in only 38% of cases. A risk management technology is the implementation of a standard operating procedure in practice, and an effective tool for analyzing non-compliance with its standards is an audit system that allows you to respond in a timely manner to existing deviations. The introduction of a system of audits of the epidemiological safety of medical technologies seems to be one of the directions of the risk-based approach to the prevention of infectious complications. Aim. To evaluate the effectiveness of hand sanitizing technology audits as a tool to reduce the risk of infections. Materials and methods . Over a three-year period, an audit of handwashing was carried out in four departments of the cardiac surgery center, during which 9924 checklists were analyzed. The audit itself took place according to the methodological recommendations we had previously developed. The audit results were processed in Microsoft Excel to form a database. Risk grading was carried out for each checklist using the risk matrix and the Percentile function in increments of 0.25 Results. During the audit, 5 items related to hand treatment technology were assessed: equipment of the workplace for hand treatment, hand treatment technology, the presence of antiseptic in areas of mandatory hand treatment, epidemiological safety during manipulation and patient care, organization of the hand treatment system. Initially, the risk in all positions was assessed as high, the implementation of corrective measures reduced the risk of infections associated with the provision of medical care to low values, and the incidence of infections in the cardiac surgery hospital decreased from 3.42 to 1.25 per 1000 patient days. Conclusion. The introduction of an audit system for hand sanitizing technology is an effective measure to reduce the risk of infection.

Epidemiology and Vaccinal PreventionVol. 23(5)
Kemerovo State Medical University (RU), Kemerovo State University (RU)
Good health and well-being
Openalex Percentile: Top 17%
Patient Safety and Medication Errors
1.49
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.