An Alternative Approach for Evaluating Induced and Contact Currents for Compliance with Their Exposure Limits (100 kHz to 110 MHz) in IEEE Std C95.1-2019

The Institute of Electrical and Electronics Engineers establishes exposure reference levels ( ERL s) for electric fields ( E -fields) (0-300 GHz) and both induced ( I IND ) and contact currents ( I SC ) (<110 MHz) in its standard, IEEE Std C95.1™-2019 (IEEE C95.1). The "classical" scenarios addressed in IEEE C95.1 include a free-standing, grounded "reference" person ( I IND ) or an ungrounded reference person in manual contact with an adjacent grounded conductor ( I SC ), each exposed to a vertically oriented E -field driving the currents. The ERL s for current from 100 kHz to 110 MHz were established to limit heating in the finger (from touch), ankle ( I IND ), and wrist ( I SC from grasp contact), specifying the 6-min average specific absorption rate ( SAR , W kg -1 ) as the dosimetric reference limit ( DRL ); whole-body E -field ERL s are 30-min averages. The DRLs were established assuming a default "effective" local cross-section (9.5 cm 2 ) and consistent with a composite tissue conductivity of ~0.5 S m -1 . A previous publication described the misalignment of the ERL s for E -fields with the ERL s for I IND (which extends to I SC ) and also proposed a ramped E -field ERL from 100 kHz to 30 MHz. For the frequency range 100 kHz to 110 MHz, this paper proposes temperature increase ( ΔT ) in ankle and wrist as the preferred effect metric associated with I IND and I SC ; applying the E -field ERL s as surrogates for limits to these currents; and adopting the proposed ramp. The analysis of ΔT is based on the tissue mix in realistic anatomic depictions of ankle and wrist cross-sections; relevant tissue properties posted online; published tissue perfusion data; and anthropometric data on a large sample of male and female adults in the US military, allowing an estimate of effects over a range of body size. To evaluate ΔT versus frequency and time, the Penne bioheat equation was adapted with convective cooling from arterial blood as the lone cooling mechanism. The analysis revealed that I IND s and I SC s induced by ERL -level E -fields produce SAR s in excess of the local DRL s (in some cases far exceed). Calculations of time to ΔT of 5 °C, reflective of a potentially adverse (painful) response, resulted in worst-case times for effects in the ankle on the order of minutes but on the order of 10s of s in wrist. Thus, compliance with the E -field ERL , as assessed as a 30-min whole-body average is incompatible with the time course of potentially adverse effects in ankle and wrist from I IND and I SC , respectively. Further analysis of the relevant exposure/dose scenarios and consensus of stakeholders with a multi-disciplinary perspective will enable the development of a revised standard, practical from a compliance perspective and protective of all persons.

Authors

Institutions

Publication Details

Journal
Health Physics
Published
2024-11-08
DOI
https://doi.org/10.1097/hp.0000000000001902
Citations
1
Primary Topic
Electromagnetic Fields and Biological Effects
Type
article
Field-Weighted Citation Impact
0.66
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

An Alternative Approach for Evaluating Induced and Contact Currents for Compliance with Their Exposure Limits (100 kHz to 110 MHz) in IEEE Std C95.1-2019

Richard A. Tell, Robert Kavet
1 citations
Health Physics
Electromagnetic Fields and Biological Effects
0.66
article

An Alternative Approach for Evaluating Induced and Contact Currents for Compliance with Their Exposure Limits (100 kHz to 110 MHz) in IEEE Std C95.1-2019

Richard A. Tell, Robert Kavet
article en
1 citations

Abstract

The Institute of Electrical and Electronics Engineers establishes exposure reference levels ( ERL s) for electric fields ( E -fields) (0-300 GHz) and both induced ( I IND ) and contact currents ( I SC ) (<110 MHz) in its standard, IEEE Std C95.1™-2019 (IEEE C95.1). The "classical" scenarios addressed in IEEE C95.1 include a free-standing, grounded "reference" person ( I IND ) or an ungrounded reference person in manual contact with an adjacent grounded conductor ( I SC ), each exposed to a vertically oriented E -field driving the currents. The ERL s for current from 100 kHz to 110 MHz were established to limit heating in the finger (from touch), ankle ( I IND ), and wrist ( I SC from grasp contact), specifying the 6-min average specific absorption rate ( SAR , W kg -1 ) as the dosimetric reference limit ( DRL ); whole-body E -field ERL s are 30-min averages. The DRLs were established assuming a default "effective" local cross-section (9.5 cm 2 ) and consistent with a composite tissue conductivity of ~0.5 S m -1 . A previous publication described the misalignment of the ERL s for E -fields with the ERL s for I IND (which extends to I SC ) and also proposed a ramped E -field ERL from 100 kHz to 30 MHz. For the frequency range 100 kHz to 110 MHz, this paper proposes temperature increase ( ΔT ) in ankle and wrist as the preferred effect metric associated with I IND and I SC ; applying the E -field ERL s as surrogates for limits to these currents; and adopting the proposed ramp. The analysis of ΔT is based on the tissue mix in realistic anatomic depictions of ankle and wrist cross-sections; relevant tissue properties posted online; published tissue perfusion data; and anthropometric data on a large sample of male and female adults in the US military, allowing an estimate of effects over a range of body size. To evaluate ΔT versus frequency and time, the Penne bioheat equation was adapted with convective cooling from arterial blood as the lone cooling mechanism. The analysis revealed that I IND s and I SC s induced by ERL -level E -fields produce SAR s in excess of the local DRL s (in some cases far exceed). Calculations of time to ΔT of 5 °C, reflective of a potentially adverse (painful) response, resulted in worst-case times for effects in the ankle on the order of minutes but on the order of 10s of s in wrist. Thus, compliance with the E -field ERL , as assessed as a 30-min whole-body average is incompatible with the time course of potentially adverse effects in ankle and wrist from I IND and I SC , respectively. Further analysis of the relevant exposure/dose scenarios and consensus of stakeholders with a multi-disciplinary perspective will enable the development of a revised standard, practical from a compliance perspective and protective of all persons.

Health PhysicsVol. 128(2)
Cadence Design Systems (United States) (US)
Openalex Percentile: Top 19%
Electromagnetic Fields and Biological Effects
0.66
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.