Neural network-based automated proptosis measurement using computed tomography images for patients with thyroid-associated orbitopathy

The purpose of this study was to evaluate the clinical feasibility and reliability of a neural network (NN)-based automated proptosis measurement system using computed tomography (CT) images. An automated proptosis measurement system was developed using the CT images of 200 eyes from 100 patients diagnosed with thyroid-associated orbitopathy. We compared the proptosis value obtained from the proposed automated system with the values obtained from the Hertel exophthalmometer and manual measurements of CT slices. The average measurement values were 17.77 ± 2.47 mm with the Hertel exophthalmometer, 18.87 ± 2.68 mm with the manual measurement of CT slices, and 19.30 ± 2.76 mm with the proposed automated system. There was no significant difference in the proptosis values measured using the manual and automated NN-based methods (p = 0.241). The values obtained from manual measurement and automated measurement using CT images showed excellent agreement with an intraclass correlation coefficient of 0.95. Based on the Bland-Altman plots, the 95% limits of agreement between manual CT and NN-based measurements were much smaller than those between Hertel exophthalmometer measurement and manual and NN-based measurements. In conclusion, automated NN-based measurements could provide a straightforward and efficient method for measuring proptosis using CT images.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2024-11-08
DOI
https://doi.org/10.1038/s41598-024-78549-2
Citations
1
Primary Topic
Ophthalmology and Eye Disorders
Type
article
Field-Weighted Citation Impact
0.42

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Neural network-based automated proptosis measurement using computed tomography images for patients with thyroid-associated orbitopathy

Jaesung Lee, Sujeong Han, Jeong Kyu Lee
1 citations
Scientific Reports
Ophthalmology and Eye Disorders
0.42
article

Neural network-based automated proptosis measurement using computed tomography images for patients with thyroid-associated orbitopathy

Jaesung Lee, Sujeong Han, Jeong Kyu Lee
article en
1 citations

Abstract

The purpose of this study was to evaluate the clinical feasibility and reliability of a neural network (NN)-based automated proptosis measurement system using computed tomography (CT) images. An automated proptosis measurement system was developed using the CT images of 200 eyes from 100 patients diagnosed with thyroid-associated orbitopathy. We compared the proptosis value obtained from the proposed automated system with the values obtained from the Hertel exophthalmometer and manual measurements of CT slices. The average measurement values were 17.77 ± 2.47 mm with the Hertel exophthalmometer, 18.87 ± 2.68 mm with the manual measurement of CT slices, and 19.30 ± 2.76 mm with the proposed automated system. There was no significant difference in the proptosis values measured using the manual and automated NN-based methods (p = 0.241). The values obtained from manual measurement and automated measurement using CT images showed excellent agreement with an intraclass correlation coefficient of 0.95. Based on the Bland-Altman plots, the 95% limits of agreement between manual CT and NN-based measurements were much smaller than those between Hertel exophthalmometer measurement and manual and NN-based measurements. In conclusion, automated NN-based measurements could provide a straightforward and efficient method for measuring proptosis using CT images.

Scientific ReportsVol. 14(1)
Chung-Ang University Hospital (KR), Chung-Ang University (KR)
National Research Foundation, Chung-Ang University, National Research Foundation of Korea, Ministry of Science and ICT, South Korea, Institute for Information and Communications Technology Promotion
Openalex Percentile: Top 33%
Ophthalmology and Eye Disorders
0.42
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Neural network-based automated proptosis measurement using computed tomography images for patients with thyroid-associated orbitopathy — Jaesung Lee, Sujeong Han, et al. · Scientific Reports (2024) | TGRS Research Map | TGRS