Analysis of the physical properties of a boron meter based on He-3 neutron detector

Boron meter is commonly used for real-time monitoring of boron concentration in the primary circuit water of pressurized water reactors to ensure the safe operation of the reactor. This paper introduces the use of Am-Be neutron source and He-3 neutron detector for a boron meter. It analyzes the physical properties of a boron meter, including the energy spectrum characteristics of Am-Be neutron sources, the sensitivity of He-3 neutron detector, radiation shielding of the boron meter’s detection device, and the fitting relationship between neutron count rate and boron concentration. The boron meter was accurately physically modeled using the MCNP program, and the calculated results were comprehensively compared with experimental results. A method using correction factor μ to adjust the count rate’s calculated results was proposed. The research results show that the sensitivity of He-3 neutron detectors, the dose rate on the surface of the boron meter detection device, neutron count rate, and other calculated results are consistent with the experimental results, verifying the accuracy of the boron physical model. This physical model can be used for more refined computational analysis or to optimize the current physical design of the boron meter, thus saving experimental costs.

Authors

Institutions

Publication Details

Journal
Alexandria Engineering Journal
Published
2024-11-08
DOI
https://doi.org/10.1016/j.aej.2024.11.013
Citations
1
Primary Topic
Nuclear Physics and Applications
Type
article
Field-Weighted Citation Impact
0.61
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analysis of the physical properties of a boron meter based on He-3 neutron detector

Can Cui, Guoen Fu, Qi-Dong Dai, Xun-Cheng Zong et al.
1 citations
Alexandria Engineering Journal
Nuclear Physics and Applications
0.61
article

Analysis of the physical properties of a boron meter based on He-3 neutron detector

Can Cui, Guoen Fu, Qi-Dong Dai, Xun-Cheng Zong, Hongbo Wang, Can-Hui Wang
article en
1 citations

Abstract

Boron meter is commonly used for real-time monitoring of boron concentration in the primary circuit water of pressurized water reactors to ensure the safe operation of the reactor. This paper introduces the use of Am-Be neutron source and He-3 neutron detector for a boron meter. It analyzes the physical properties of a boron meter, including the energy spectrum characteristics of Am-Be neutron sources, the sensitivity of He-3 neutron detector, radiation shielding of the boron meter’s detection device, and the fitting relationship between neutron count rate and boron concentration. The boron meter was accurately physically modeled using the MCNP program, and the calculated results were comprehensively compared with experimental results. A method using correction factor μ to adjust the count rate’s calculated results was proposed. The research results show that the sensitivity of He-3 neutron detectors, the dose rate on the surface of the boron meter detection device, neutron count rate, and other calculated results are consistent with the experimental results, verifying the accuracy of the boron physical model. This physical model can be used for more refined computational analysis or to optimize the current physical design of the boron meter, thus saving experimental costs.

Alexandria Engineering JournalVol. 112
Chengdu Institute of Information Technology (China) (CN), China General Nuclear Power Corporation (China) (CN)
Openalex Percentile: Top 29%
Nuclear Physics and Applications
0.61
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.