Standard Gum Elastic Bougie Versus Flexible Tip Bougie: Evaluation of Airway Adjuncts for Intubation by Paramedics in Entrapped Manikins with Difficult Airway Access—A Randomised, Controlled Trial

<b>Introduction:</b> Airway management in pre-hospital settings is often challenging and difficult to perform. This is particularly true during tracheal intubation of entrapped patients with difficult airway access. There are various airway adjuncts available in the current practice. Their aim is to facilitate tracheal intubation. One of the recently introduced devices is the flexible tip bougie. The aim of this study was to evaluate the flexible tip bougie for intubation in a simulated condition of an entrapped trauma patient with simultaneous cervical spine immobilisation. <b>Methods:</b> An intubation manikin with the cervical collar on was placed on and secured to the driver's seat of a passenger car. The car was then positioned on its left side. The first attempt success rate as well as the intubation and successful ventilation time were recorded. The ease of use by the operator and user-friendliness were also assessed. <b>Results:</b> The standard gum elastic bougie required the shortest mean intubation to successful ventilation time, 38.4 s (±9.6) vs. 41.4 s (±6.8), <i>p</i> = 0.46. The first attempt success rate was higher in the standard gum elastic bougie group, 92% vs. 88%, <i>p</i> = 0.04. There were no failed intubations when the standard gum elastic bougie was used. The flexible tip bougie was found to be more difficult to use and less user-friendly, 7.6 (±1.5) vs. 5.8 (±2.9), <i>p</i> = 0.02. <b>Conclusions:</b> The standard gum elastic bougie was superior in terms of the first attempt success and the time required for intubation and successful ventilation. Moreover, it was found to be easier to use and more user-friendly.

Authors

Institutions

Publication Details

Journal
Healthcare
Published
2024-11-08
DOI
https://doi.org/10.3390/healthcare12222232
Citations
2
Primary Topic
Airway Management and Intubation Techniques
Type
article
Field-Weighted Citation Impact
1.28
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Standard Gum Elastic Bougie Versus Flexible Tip Bougie: Evaluation of Airway Adjuncts for Intubation by Paramedics in Entrapped Manikins with Difficult Airway Access—A Randomised, Controlled Trial

Dawid Aleksandrowicz, Paweł Ratajczyk
2 citations
Healthcare
Airway Management and Intubation Techniques
1.28
article

Standard Gum Elastic Bougie Versus Flexible Tip Bougie: Evaluation of Airway Adjuncts for Intubation by Paramedics in Entrapped Manikins with Difficult Airway Access—A Randomised, Controlled Trial

Dawid Aleksandrowicz, Paweł Ratajczyk
article en
2 citations

Abstract

<b>Introduction:</b> Airway management in pre-hospital settings is often challenging and difficult to perform. This is particularly true during tracheal intubation of entrapped patients with difficult airway access. There are various airway adjuncts available in the current practice. Their aim is to facilitate tracheal intubation. One of the recently introduced devices is the flexible tip bougie. The aim of this study was to evaluate the flexible tip bougie for intubation in a simulated condition of an entrapped trauma patient with simultaneous cervical spine immobilisation. <b>Methods:</b> An intubation manikin with the cervical collar on was placed on and secured to the driver's seat of a passenger car. The car was then positioned on its left side. The first attempt success rate as well as the intubation and successful ventilation time were recorded. The ease of use by the operator and user-friendliness were also assessed. <b>Results:</b> The standard gum elastic bougie required the shortest mean intubation to successful ventilation time, 38.4 s (±9.6) vs. 41.4 s (±6.8), <i>p</i> = 0.46. The first attempt success rate was higher in the standard gum elastic bougie group, 92% vs. 88%, <i>p</i> = 0.04. There were no failed intubations when the standard gum elastic bougie was used. The flexible tip bougie was found to be more difficult to use and less user-friendly, 7.6 (±1.5) vs. 5.8 (±2.9), <i>p</i> = 0.02. <b>Conclusions:</b> The standard gum elastic bougie was superior in terms of the first attempt success and the time required for intubation and successful ventilation. Moreover, it was found to be easier to use and more user-friendly.

HealthcareVol. 12(22)
Medical University of Lodz (PL)
Openalex Percentile: Top 18%
Airway Management and Intubation Techniques
1.28
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Standard Gum Elastic Bougie Versus Flexible Tip Bougie: Evaluation of Airway Adjuncts for Intubation by Paramedics in Entrapped Manikins with Difficult Airway Access—A Randomised, Controlled Trial — Dawid Aleksandrowicz, Paweł Ratajczyk · Healthcare (2024) | TGRS Research Map | TGRS