Lidocaine nebulization for airway topical anesthesia can be improved by diminish ex-cannula lost and alkalization

• Ultrasound lidocaine nebulization did not provide adequate airway topical anesthesia due a huge wastage of lidocaine aerosol and low pH of lidocaine preparation. • Diminish ex-cannula lost will markedly improve the lidocaine nebulization for bronchoscopy anesthesia. • Enhance lidocaine pH will improve lidocaine airway topical anesthesia. Lidocaine nebulization is noninvasive, safe, and easy to perform. However, it does not provide adequate anesthesia due to the following reasons: 1. There is a high wastage of lidocaine aerosol, with at least 70 % of the lidocaine aerosol being lost from the cannula. This loss of lidocaine results in a lower amount of inhaled lidocaine, which is insufficient to provide adequate anesthesia. 2. The commercial lidocaine preparation has a low penetrating potency. The onset of anesthesia is directly related to the amount of local anesthetic in the lipid-soluble form. However, there are only a few lipid-soluble prototypes in the commercially available lidocaine cartridges. This is because the lidocaine is purposely formulated as acidic solutions (with pH levels between 3.5 and 5.5) in order to enhance the solubility and stability of the anesthetic salts. To address these issues and improve lidocaine anesthesia potency while reducing wastage, a “Y” type cannula was used for aerosol inhalation. Additionally, 1/5 vol of 5 % sodium bicarbonate solution was added to 2 % lidocaine to enhance the pH value to 7.2. This alkalized lidocaine nebulization provides an effective topical anesthesia for bronchoscopy.

Authors

Institutions

Publication Details

Journal
Medical Hypotheses
Published
2024-11-08
DOI
https://doi.org/10.1016/j.mehy.2024.111511
Primary Topic
Airway Management and Intubation Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Lidocaine nebulization for airway topical anesthesia can be improved by diminish ex-cannula lost and alkalization

Senming Zhao, Ran Duan, Yanxin Cheng, Lei Zhang et al.
Medical Hypotheses
Airway Management and Intubation Techniques
article

Lidocaine nebulization for airway topical anesthesia can be improved by diminish ex-cannula lost and alkalization

Senming Zhao, Ran Duan, Yanxin Cheng, Lei Zhang, Yingying Zhang
article en

Abstract

• Ultrasound lidocaine nebulization did not provide adequate airway topical anesthesia due a huge wastage of lidocaine aerosol and low pH of lidocaine preparation. • Diminish ex-cannula lost will markedly improve the lidocaine nebulization for bronchoscopy anesthesia. • Enhance lidocaine pH will improve lidocaine airway topical anesthesia. Lidocaine nebulization is noninvasive, safe, and easy to perform. However, it does not provide adequate anesthesia due to the following reasons: 1. There is a high wastage of lidocaine aerosol, with at least 70 % of the lidocaine aerosol being lost from the cannula. This loss of lidocaine results in a lower amount of inhaled lidocaine, which is insufficient to provide adequate anesthesia. 2. The commercial lidocaine preparation has a low penetrating potency. The onset of anesthesia is directly related to the amount of local anesthetic in the lipid-soluble form. However, there are only a few lipid-soluble prototypes in the commercially available lidocaine cartridges. This is because the lidocaine is purposely formulated as acidic solutions (with pH levels between 3.5 and 5.5) in order to enhance the solubility and stability of the anesthetic salts. To address these issues and improve lidocaine anesthesia potency while reducing wastage, a “Y” type cannula was used for aerosol inhalation. Additionally, 1/5 vol of 5 % sodium bicarbonate solution was added to 2 % lidocaine to enhance the pH value to 7.2. This alkalized lidocaine nebulization provides an effective topical anesthesia for bronchoscopy.

Medical HypothesesVol. 194
Hebei Medical University (CN), Third Hospital of Hebei Medical University (CN), Xingtai People's Hospital (CN)
Clean water and sanitation
Openalex Percentile: Top 63%
Airway Management and Intubation Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Lidocaine nebulization for airway topical anesthesia can be improved by diminish ex-cannula lost and alkalization — Senming Zhao, Ran Duan, et al. · Medical Hypotheses (2024) | TGRS Research Map | TGRS