Effect of electrode size and distance to tissue on unipolar and bipolar voltage electrograms and their implications for a near-field cutoff
Characteristics of electrograms depend on the electrode design and distance to the electric source. Our aim was to assess the impact of electrode design and distance from the myocardial electric source on the unipolar and bipolar electrograms to deduce a far-field cut-off. We retrospectively analyzed left atrial electroanatomical maps of 25 patients acquired using an ablation catheter with a 4.5 mm tip-, mini- and 2 mm ring electrodes. The unipolar and bipolar electrograms were characterized based on peak-to-peak amplitude, signal duration, maximal slope, and relative power of the high frequency spectrum above 50 Hz (HF_rel). The unipolar electrograms of ring electrodes showed an increased amplitude (140%), slope (150%) and HF_rel (16% vs. 11%) compared to the tip- and mini-electrodes. The median amplitude, slope, and HF_rel for the ring electrodes followed a power-law decay with distance with a steep decline up to 4 mm. This near-field cut-off can be identified based on a HF_rel above 10% in unipolar electrograms. In conclusion, we observed a higher unipolar amplitude for small ring-electrodes compared to larger tip-electrodes. The rapid decay of the amplitude, slope, and HF_rel up to a distance of 4 mm is suggestive for near-field cut-off identified based on HF_rel above 50 Hz.Clinical Trial Registration: NCT04095559.
Authors
- Philipp Krisai (ORCID: https://orcid.org/0000-0002-4367-2363)
- Adrian Luca (ORCID: https://orcid.org/0000-0002-0040-8191)
- Thomas Kueffer (ORCID: https://orcid.org/0000-0003-3553-4945)
- Stefan Osswald (ORCID: https://orcid.org/0000-0002-9240-6731)
- Vincent Schlageter (ORCID: https://orcid.org/0000-0001-6305-5103)
- Michael Kühne (ORCID: https://orcid.org/0000-0002-2937-3711)
- Beat Schaer (ORCID: https://orcid.org/0000-0003-1768-1968)
- Patrick Badertscher (ORCID: https://orcid.org/0000-0001-9751-0557)
- Sven Knecht (ORCID: https://orcid.org/0000-0001-7122-021X)
- Christian Sticherling (ORCID: https://orcid.org/0000-0001-8428-7050)
- Josip Katić (ORCID: https://orcid.org/0000-0002-4991-1919)
- David Spreen
Institutions
- University of Bern (CH)
- University of Basel (CH)
- University Hospital of Bern (CH)
- University Hospital of Basel (CH)
- Hospital Base (CL)
- University of Lausanne (CH)
Publication Details
- Journal
- Scientific Reports
- Published
- 2024-11-08
- DOI
- https://doi.org/10.1038/s41598-024-78627-5
- Citations
- 4
- Primary Topic
- Cardiac electrophysiology and arrhythmias
- Type
- article
- Field-Weighted Citation Impact
- 1.61
Funders
- National Science Foundation
- Foundation for Cardiovascular Research
- Universität Basel
- Boston Scientific Corporation
- European Commission
- Schweizerischer Nationalfonds zur Förderung der Wissenschaftlichen Forschung
- Schweizerische Herzstiftung
- MicroPort
- Biosense Webster