Effect of electrode size and distance to tissue on unipolar and bipolar voltage electrograms and their implications for a near-field cutoff

Characteristics of electrograms depend on the electrode design and distance to the electric source. Our aim was to assess the impact of electrode design and distance from the myocardial electric source on the unipolar and bipolar electrograms to deduce a far-field cut-off. We retrospectively analyzed left atrial electroanatomical maps of 25 patients acquired using an ablation catheter with a 4.5 mm tip-, mini- and 2 mm ring electrodes. The unipolar and bipolar electrograms were characterized based on peak-to-peak amplitude, signal duration, maximal slope, and relative power of the high frequency spectrum above 50 Hz (HF_rel). The unipolar electrograms of ring electrodes showed an increased amplitude (140%), slope (150%) and HF_rel (16% vs. 11%) compared to the tip- and mini-electrodes. The median amplitude, slope, and HF_rel for the ring electrodes followed a power-law decay with distance with a steep decline up to 4 mm. This near-field cut-off can be identified based on a HF_rel above 10% in unipolar electrograms. In conclusion, we observed a higher unipolar amplitude for small ring-electrodes compared to larger tip-electrodes. The rapid decay of the amplitude, slope, and HF_rel up to a distance of 4 mm is suggestive for near-field cut-off identified based on HF_rel above 50 Hz.Clinical Trial Registration: NCT04095559.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2024-11-08
DOI
https://doi.org/10.1038/s41598-024-78627-5
Citations
4
Primary Topic
Cardiac electrophysiology and arrhythmias
Type
article
Field-Weighted Citation Impact
1.61

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effect of electrode size and distance to tissue on unipolar and bipolar voltage electrograms and their implications for a near-field cutoff

Philipp Krisai, Adrian Luca, Thomas Kueffer, Stefan Osswald et al.
4 citations
Scientific Reports
Cardiac electrophysiology and arrhythmias
1.61
article

Effect of electrode size and distance to tissue on unipolar and bipolar voltage electrograms and their implications for a near-field cutoff

Philipp Krisai, Adrian Luca, Thomas Kueffer, Stefan Osswald, Vincent Schlageter, Michael Kühne, Beat Schaer, Patrick Badertscher, Sven Knecht, Christian Sticherling, Josip Katić, David Spreen
article en
4 citations

Abstract

Characteristics of electrograms depend on the electrode design and distance to the electric source. Our aim was to assess the impact of electrode design and distance from the myocardial electric source on the unipolar and bipolar electrograms to deduce a far-field cut-off. We retrospectively analyzed left atrial electroanatomical maps of 25 patients acquired using an ablation catheter with a 4.5 mm tip-, mini- and 2 mm ring electrodes. The unipolar and bipolar electrograms were characterized based on peak-to-peak amplitude, signal duration, maximal slope, and relative power of the high frequency spectrum above 50 Hz (HF_rel). The unipolar electrograms of ring electrodes showed an increased amplitude (140%), slope (150%) and HF_rel (16% vs. 11%) compared to the tip- and mini-electrodes. The median amplitude, slope, and HF_rel for the ring electrodes followed a power-law decay with distance with a steep decline up to 4 mm. This near-field cut-off can be identified based on a HF_rel above 10% in unipolar electrograms. In conclusion, we observed a higher unipolar amplitude for small ring-electrodes compared to larger tip-electrodes. The rapid decay of the amplitude, slope, and HF_rel up to a distance of 4 mm is suggestive for near-field cut-off identified based on HF_rel above 50 Hz.Clinical Trial Registration: NCT04095559.

Scientific ReportsVol. 14(1)
University of Bern (CH), University of Basel (CH), University Hospital of Bern (CH), University Hospital of Basel (CH), Hospital Base (CL), University of Lausanne (CH)
National Science Foundation, Foundation for Cardiovascular Research, Universität Basel, Boston Scientific Corporation, European Commission, Schweizerischer Nationalfonds zur Förderung der Wissenschaftlichen Forschung, Schweizerische Herzstiftung, MicroPort, Biosense Webster
Openalex Percentile: Top 14%
Cardiac electrophysiology and arrhythmias
1.61
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.