Multiple Defect‐Induced High‐Resolution Near‐Infrared Mechanoluminescent Materials for Non‐Destructive Detection of Blood Glucose and Lipids

Mechanoluminescence (ML) materials, known for their ability to convert mechanical energy into light, are increasingly recognized for their potential applications, such as in intelligent stress sensing, in vivo bioimaging, and stress non-destructive monitoring. However, the low signal-to-noise ratio (SNR) and narrow-band emission of single-defect-induced ML materials usually limit their biological-related practical applications. Here, these limitations will be addressed by modulating the microstructure evolution in Y<sub>3</sub>Ga<sub>3</sub>MgSiO<sub>12</sub>:Cr<sup>3+</sup> through the [Si<sup>4+</sup>+Mg<sup>2+</sup>] → [Ga<sup>3+</sup>+Ga<sup>3+</sup>] chemical substitution strategy. Density functional theory (DFT) calculation reveals the defect types and dynamic charge migration processes. In addition, Y<sub>3</sub>Ga<sub>3</sub>MgSiO<sub>12</sub>: Cr<sup>3+</sup> with continuously distributed "shallow-deep" defects (0.68-1.61 eV) can avoid persistent luminescence (PersL) and bright-field environment interference. Herein, such high SNR near-infrared broadband ML emission may provide a reliable way for high-quality biological non-destructive sensing and detection. Finally, benefiting from the different absorption of ML signals in glucose/lipid, one may find a novel non-invasive blood glucose/lipid testing technology in patients.

Authors

Institutions

Publication Details

Journal
Advanced Materials
Published
2024-11-06
DOI
https://doi.org/10.1002/adma.202408508
Citations
67
Primary Topic
Luminescence and Fluorescent Materials
Type
article
Field-Weighted Citation Impact
7.85

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Multiple Defect‐Induced High‐Resolution Near‐Infrared Mechanoluminescent Materials for Non‐Destructive Detection of Blood Glucose and Lipids

Zhi-Gang Shao, Binli Xiao, Guangyu Zhou, Peishan Shao et al.
67 citations
Advanced Materials
Luminescence and Fluorescent Materials
7.85
article

Multiple Defect‐Induced High‐Resolution Near‐Infrared Mechanoluminescent Materials for Non‐Destructive Detection of Blood Glucose and Lipids

Zhi-Gang Shao, Binli Xiao, Guangyu Zhou, Peishan Shao, Yinzhen Wang, Yafen Wu, Shouping Wang, Sheng Wu, Puxian Xiong, Feifei Wang, Yao Xiao, Zhiyao Zhou
article en
67 citations

Abstract

Mechanoluminescence (ML) materials, known for their ability to convert mechanical energy into light, are increasingly recognized for their potential applications, such as in intelligent stress sensing, in vivo bioimaging, and stress non-destructive monitoring. However, the low signal-to-noise ratio (SNR) and narrow-band emission of single-defect-induced ML materials usually limit their biological-related practical applications. Here, these limitations will be addressed by modulating the microstructure evolution in Y<sub>3</sub>Ga<sub>3</sub>MgSiO<sub>12</sub>:Cr<sup>3+</sup> through the [Si<sup>4+</sup>+Mg<sup>2+</sup>] → [Ga<sup>3+</sup>+Ga<sup>3+</sup>] chemical substitution strategy. Density functional theory (DFT) calculation reveals the defect types and dynamic charge migration processes. In addition, Y<sub>3</sub>Ga<sub>3</sub>MgSiO<sub>12</sub>: Cr<sup>3+</sup> with continuously distributed "shallow-deep" defects (0.68-1.61 eV) can avoid persistent luminescence (PersL) and bright-field environment interference. Herein, such high SNR near-infrared broadband ML emission may provide a reliable way for high-quality biological non-destructive sensing and detection. Finally, benefiting from the different absorption of ML signals in glucose/lipid, one may find a novel non-invasive blood glucose/lipid testing technology in patients.

Advanced MaterialsVol. 36(50)
South China Normal University (CN), Education University of Hong Kong (HK), Third Affiliated Hospital of Guangzhou Medical University (CN), Key Laboratory of Guangdong Province (CN), State Key Laboratory of Luminescent Materials and Devices, University of Hong Kong (HK), South China University of Technology (CN), Guangzhou Medical University (CN)
National Natural Science Foundation of China
Openalex Percentile: Top 1%
Luminescence and Fluorescent Materials
7.85
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.