Multiple Defect‐Induced High‐Resolution Near‐Infrared Mechanoluminescent Materials for Non‐Destructive Detection of Blood Glucose and Lipids
Mechanoluminescence (ML) materials, known for their ability to convert mechanical energy into light, are increasingly recognized for their potential applications, such as in intelligent stress sensing, in vivo bioimaging, and stress non-destructive monitoring. However, the low signal-to-noise ratio (SNR) and narrow-band emission of single-defect-induced ML materials usually limit their biological-related practical applications. Here, these limitations will be addressed by modulating the microstructure evolution in Y<sub>3</sub>Ga<sub>3</sub>MgSiO<sub>12</sub>:Cr<sup>3+</sup> through the [Si<sup>4+</sup>+Mg<sup>2+</sup>] → [Ga<sup>3+</sup>+Ga<sup>3+</sup>] chemical substitution strategy. Density functional theory (DFT) calculation reveals the defect types and dynamic charge migration processes. In addition, Y<sub>3</sub>Ga<sub>3</sub>MgSiO<sub>12</sub>: Cr<sup>3+</sup> with continuously distributed "shallow-deep" defects (0.68-1.61 eV) can avoid persistent luminescence (PersL) and bright-field environment interference. Herein, such high SNR near-infrared broadband ML emission may provide a reliable way for high-quality biological non-destructive sensing and detection. Finally, benefiting from the different absorption of ML signals in glucose/lipid, one may find a novel non-invasive blood glucose/lipid testing technology in patients.
Authors
- Zhi-Gang Shao (ORCID: https://orcid.org/0000-0002-1639-7597)
- Binli Xiao
- Guangyu Zhou (ORCID: https://orcid.org/0000-0003-2660-3654)
- Peishan Shao
- Yinzhen Wang (ORCID: https://orcid.org/0000-0002-4939-1319)
- Yafen Wu
- Shouping Wang
- Sheng Wu (ORCID: https://orcid.org/0000-0002-2683-2986)
- Puxian Xiong (ORCID: https://orcid.org/0000-0002-2065-2968)
- Feifei Wang (ORCID: https://orcid.org/0000-0002-6667-912X)
- Yao Xiao (ORCID: https://orcid.org/0000-0002-2820-2937)
- Zhiyao Zhou
Institutions
- South China Normal University (CN)
- Education University of Hong Kong (HK)
- Third Affiliated Hospital of Guangzhou Medical University (CN)
- Key Laboratory of Guangdong Province (CN)
- State Key Laboratory of Luminescent Materials and Devices
- University of Hong Kong (HK)
- South China University of Technology (CN)
- Guangzhou Medical University (CN)
Publication Details
- Journal
- Advanced Materials
- Published
- 2024-11-06
- DOI
- https://doi.org/10.1002/adma.202408508
- Citations
- 67
- Primary Topic
- Luminescence and Fluorescent Materials
- Type
- article
- Field-Weighted Citation Impact
- 7.85
Funders
- National Natural Science Foundation of China